加油站应急预案 目录 一、总 则∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2 二、加油站火灾爆炸应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8 三、加油站跑冒油品应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙11 四、加油站混油应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙15 五、加油站治安事件应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙17 六、加油站洪汛灾害应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙19 七、加油站成品油供应短缺应急预案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙21 八、加油站外线停电应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙23 九、加油站交通事故应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙25 十、加油站防台风应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙27 十一、加油站卫生健康应急预案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙28 十二、加油站防雷击应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙31 十三、加油站数质量纠纷、媒体曝光、系统外检查应急预 案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙33 十四、加油站地震灾害应急预案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙36 十五、附件∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙38 一、总 则 一、编制目的 为了全面贯彻落实“安全第一、预防为主”的HSE方针,规范加 油站的应急事件管理工作,提高对突发事件的应急救援反应速度, 增强加油站综合处置应急事件的能力,保障企业员工和公众安全, 最大限度减少财产损失、环境破坏和社会影响,特制定本预案。 二、编制依据 中华人民共和国安全生产法 中华人民共和国消防法 中华人民共和国环境保护法 中华人民共和国防洪法 国家突发公共事件总体应急预案 中国石化重特大事件应急预案 中国石油化工股份有限公司内部控制制度(2007版) 中国石油化工股份有限公司湖南石油分公司HSE管理体系实 施程序(2005年1月1日向社会发布实施) 《中国石化湖南石油分公司总体应急预案》(2007年) 三、工作原则 ⒈以人为本、减少危害的原则。最大限度减少人员伤亡和财 产损失,把事故危害降到最低点,维护加油站安全和社会稳定。
分类:事故与应急 行业:其它行业 文件类型:Word 文件大小:202 KB 时间:2025-08-12 价格:¥2.00
安全生产、职业健康、环保责任书 甲方: (班组长) ,以下简称甲方 乙方: 谭少华 (班组工人) ,以下简称乙方 为进一步贯彻“安全第一,预防为主,综合治理”的安全生产方针,牢牢坚守“发 展决不能以牺牲人的生命为代价”红线,建立健全“党政同责、一岗双责、齐抓共 管”的安全监管基本框架,有效遏制职业健康、安全环保、安全生产责任事故发生, 结合本项目工程实际,特签订本责任书,以明确双方的责任和义务。 一、甲方责任清单 1、认真学习并贯彻执行项目有关安全生产的规章制度,以身作则,带头遵 守各项安全操作规程,及时纠正违章作业,对本工班(组)作业人员的生产安全 与健康负直接管理责任。 2、带领本工班(组)工人严格执行安全技术操作规程,遵守劳动纪律,听 从管理人员安全生产指导,制止“三违行为”,保证按正确方法施工;尤其对新工、 青工,更要加强安全教育和实际指导,必要时亲自示范。 3、认真执行安全技术交底制度,对不具备安全生产条件、人身安全得不到 保障的工程任务,有权拒绝施工,必要时可越级向上级领导或安监部门反映。 4、落实班前讲话活动,在班前对作业人员进行简明、实用的安全教育,提 高作业人员的安全意识,并将讲话现场录像,定期提交项目部安环部归档留存。 5、合理安排劳动力,严格控制加班、加点;根据当天的生产任务和每个工 人的思想动态、身体状况,具体布置其生产岗位,对不按时作息的人员要进行教 育,以保证其休息,避免事故发生.确保安全生产。 6、工作前必须先进入工地,对工地、工具、机电设备的安全情况进行检查, 坚持交接班制,发现问题及时解决,并将注意事项向本班组作业人员交待清楚; 保证本工班(组)的安全防护设施和个人劳动防护用品的正确使用。对不能解决 的问题,立即报告上级处理。 7、负责支持配备到工班(组)的兼职安全员工作,并发挥他们的作用。 8、自觉接受上级领导、有关方面和安监人员的安全监督检查,对检查中提 出的问题及时认真进行整改,不留隐患。 9、有权拒绝上级的违章指挥。遇有紧急险情,有权立即带领工人撤离现场, 并立即报告工地负责人及时组织排除险情。 10、对发现违章指挥、违章作业、违犯劳动纪律的“三违”行为不予制止及发 现事故隐患不予及时消除而导致的人身伤亡事故,承担直接领导责任。 11、积极参加抢险救灾活动。发生伤亡事故时要积极抢救伤员,保护现场, 并立即如实上报,组织本班组作业人员协助事故调查和分析工作。协助专职安全 生产监督管理员负责对未遂事故的分析、追查、处理。 12、因现场管理控制不严或不遵守安全生产相关文件要求而导致的人员伤 亡,建筑、车辆、机械损坏的,施工队伍须承担因此而发生的全部损失费用。 二、乙方责任清单 1、作业人员必须按照要求正确、完整地穿戴劳保防护用品。 2、认真贯彻执行安全生产的各项规章制度,提高安全生产意识,增强自我 防护意识,服从管理人员管理,及时纠正安全检查中发现的问题。 3、文明施工,不酒后上岗,不在施工现场吸烟,不随地乱扔垃圾。 4、施工中出现恶心、头晕、视野模糊等身体不适情况,必须立即停止工作。5、 作业前应重点检查下列项目符合要求: ①燃、润油料添加充足,电源正常。 ②连接及传动部位紧固,各运动机构及各部阀门开闭灵活,管路不漏气。 ③各防护装置齐全完好,储气罐内无存水。
分类:安全操作规程 行业:其它行业 文件类型:Word 文件大小:27 KB 时间:2025-10-09 价格:¥2.00
类别 排查项 检查标准 安全隐患描述 1、依法须经批准的项目,经相关部门批准后开展经营活动 2、企业营业执照记载的事项发生变更,及时换发营业执照 依法须经批准的项目,未经相关部门批准就开展经 营活动 3、有采矿许可证和施工单位、监理单位的相关资质证明 4、采矿许可证和施工单位、监理单位的相关资质证明在有效期内 5、有安全生产许可证。安全生产许可证有效期为3年 6、安全生产许可证在有效期内 7、单位名称、主要负责人、单位地址、经济类型、许可范围发生变化 时,应办理安全生产许可证变更手续 8、矿山企业、施工单位应设置专门从事安全生产管理的机构,配备安 全生产管理人员 9、安全生产管理机构和人员以文件形式进行设置或任命 10、设置或配备符合国家、北京市的要求 设置或配备不符合国家、北京市的要求 11、企业内部应当设置事故隐患排查治理的专业技术队伍 12、在企业内部公布专业技术队伍名单 13、由专职安全生产管理人员及专业技术人员担任事故隐患排查治理的 专业人员 14、责任制(含事故隐患排查治理责任制)以正式文件在企业内部下发 安全生产责任中包含事故隐患排查治理内容的,视同有事故隐患排查治 理责任制 责任制中无事故隐患排查治理内容且无事故隐患排 查治理责任制或者有事故隐患排查治理责任制但未 正式发布 15、安全责任制中明确各岗位的责任人员 安全责任制中未明确各岗位的责任人员 16、责任制要明确考核机制 责任制中未明确考核机制 17、有考核记录 18、建立纵向到底、横向到边、人人有责的安全生产责任体系,与所有 部门、班组、职工签订安全生产目标责任状。矿山企业应当建立健全行 政领导岗位安全生产责任制、职能机构安全生产责任制、岗位人员的安 全生产责任制 19、建立健全本单位安全生产责任制 未建立健全本单位安全生产责任制 隐患排查标准 资质证照 营业执照 安全生产许可证 采矿许可证 安全管理机 构或人员 安全管理机构 责任制制度 类别 排查项 检查标准 安全隐患描述 20、组织制定本单位安全生产规章制度和操作规程 未组织制定本单位安全生产规章制度和操作规程 21、保证本单位安全生产投入的有效实施 未保证本单位安全生产投入的有效实施 22、督促检查本单位的安全生产工作,及时消除生产安全事故隐患 未督促检查本单位的安全生产工作,及时消除生产 安全事故隐患 23、组织制定并实施本单位的生产安全事故应急救援预案 未组织制定并实施本单位的生产安全事故应急救援 预案 24、及时如实报告生产安全事故 未及时如实报告生产安全事故 25、组织制定并实施本单位安全生产教育和培训计划 未组织制定并实施本单位安全生产教育和培训计划 26、企业主要负责人(实际控制人)是安全生产第一责任人,事故隐患 排查治理职责至少应包括以下内容: 企业主要负责人(实际控制人)是安全生产第一责 任人,事故隐患排查治理职责至少应包括以下内 容: 27、建立健全并督促落实事故隐患排查治理责任制,包括确定职责、批 准责任制文本、对各级人员责任制落实情况进行考核奖惩等 未建立健全并督促落实事故隐患排查治理责任制, 包括确定职责、批准责任制文本、对各级人员责任 制落实情况进行考核奖惩等 28、组织制定并督促落实事故隐患排查治理的各项制度、组织制定事故 隐患排查判定标准和考核奖惩标准 未组织制定并督促落实事故隐患排查治理的各项制 度、组织制定事故隐患排查判定标准和考核奖惩标 准 29、保障事故隐患排查治理的资金投入,包括批准或向投资决策机构、 投资人申报事故隐患排查治理费用等 未保障事故隐患排查治理的资金投入,包括批准或 向投资决策机构、投资人申报事故隐患排查治理费 用等 30、定期组织并参加事故隐患排查 未定期组织并参加事故隐患排查 31、组织企业事故隐患的治理,及时事故消除事故隐患,包括组织重大 事故隐患上报、批准重要的事故隐患治理方案、定期听取事故隐患排查 治理情况汇报,组织对事故隐患治理效果进行评估等 未组织企业事故隐患的治理,及时事故消除事故隐 患,包括组织重大事故隐患上报、批准重要的事故 隐患治理方案、定期听取事故隐患排查治理情况汇 报,组织对事故隐患治理效果进行评估等 32、组织或者参与拟订本单位安全生产规章制度、操作规程和生产安全 事故应急救援预案 未组织或者参与拟订本单位安全生产规章制度、操 作规程和生产安全事故应急救援预案 33、组织或者参与本单位安全生产教育和培训,如实记录安全生产教育 和培训情况 未组织或者参与本单位安全生产教育和培训,如实 记录安全生产教育和培训情况 34、督促落实本单位重大危险源的安全管理措施 未督促落实本单位重大危险源的安全管理措施 35、组织或者参与本单位应急救援演练 未组织或者参与本单位应急救援演练 安全生产责 任制 主要负责人或实际 控制人安全职责
分类:安全管理制度 行业:采矿冶金行业 文件类型:Excel 文件大小:107 KB 时间:2025-10-17 价格:¥2.00
加油站应急预案 目录 一、总 则∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙2 二、加油站火灾爆炸应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8 三、加油站跑冒油品应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙11 四、加油站混油应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙15 五、加油站治安事件应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙17 六、加油站洪汛灾害应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙19 七、加油站成品油供应短缺应急预案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙21 八、加油站外线停电应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙23 九、加油站交通事故应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙25 十、加油站防台风应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙27 十一、加油站卫生健康应急预案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙28 十二、加油站防雷击应急预案 ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙31 十三、加油站数质量纠纷、媒体曝光、系统外检查应急预 案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙33 十四、加油站地震灾害应急预案∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙36 十五、附件∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙38 一、总 则 一、编制目的 为了全面贯彻落实“安全第一、预防为主”的HSE方针,规范加 油站的应急事件管理工作,提高对突发事件的应急救援反应速度, 增强加油站综合处置应急事件的能力,保障企业员工和公众安全, 最大限度减少财产损失、环境破坏和社会影响,特制定本预案。 二、编制依据 中华人民共和国安全生产法 中华人民共和国消防法 中华人民共和国环境保护法 中华人民共和国防洪法 国家突发公共事件总体应急预案 中国石化重特大事件应急预案 中国石油化工股份有限公司内部控制制度(2007版) 中国石油化工股份有限公司湖南石油分公司HSE管理体系实 施程序(2005年1月1日向社会发布实施) 《中国石化湖南石油分公司总体应急预案》(2007年) 三、工作原则 ⒈以人为本、减少危害的原则。最大限度减少人员伤亡和财 产损失,把事故危害降到最低点,维护加油站安全和社会稳定。
分类:事故与应急 行业:其它行业 文件类型:Word 文件大小:202 KB 时间:2025-10-22 价格:¥2.00
施工升降机操作安全技术交底 GDAQ330605 施工单位: 工程名称 分部分项 工 程 工种 一、进入施工现场必须遵守安全操作规程和安全生产纪律,操作工人必须取得省级建设主管部门颁 发的建筑施工特种作业人员操作证书,方可上岗。 二、施工升降机运行作业前重点检查项目(每天检查内容)应符合下列要求: (一)各部结构无变形,连接螺栓无松动; (二)齿条与齿轮、导向轮与导轨均接合正常; (三)各部钢丝绳固定良好,无异常磨损; (四)检查电缆导向上下,安全保护开关以及电磁制动器是否灵敏可靠。 (五)在传动机械运转时是否有噪声以及有异常声响。 (六)门的开启关闭电锁状况是否良好。 (七)运行范围内无障碍。 (八)仔细阅读上一班司机写的运转记录,以便了解机械状况。 三、启动前,应检查并确认电缆、接地线完整无损,控制开关在零位。电源接通后,应检查并确认 电压正常,应测试无漏电现象。应试验并确认各限位装置、吊笼、围护门等处的电器联锁装置良好可靠, 电器仪表灵敏有效。启动后,应进行空载升降试验 测定各传动机构制动器的效能,确认正常后,方可开 始作业。 四、升降机在每班首次载重运行时,当吊笼升离地面 1~2m 时,应停机试验制动器的可靠性;当发 现制动效果不良时,应调整或修复后方可运行。 五、吊笼内乘人或载物时,应使载荷均匀分布,不得偏重严禁超载运行。 六、操作人员应根据信号操作,作业前应鸣声示意在升降机未切断总电源开关前,操作人员不得离 开操作岗位。 七、当升降机运行中发现有异常情况时,应立即停机并采取有效措施将吊笼降到底层,排除故障后 方可继续运行。在运行中发现电气失控时,应立即按下急停按钮,在未排除故障前,不得打开急停按钮。 八、升降机在大雨、大雾、六级及以上大风以及导轨架、电缆等结冰时、必须停止运行,并将吊笼 降到底层切断电源暴风雨后,应对升降机各有关安全装置进行一次检查,确认正常后,方可运行。 九、升降机运行到最上层或最下层时,严禁用行程限位开关作为停止运行的控制开关。 十、当升降机在运行中由于断电或其他原因而中途停止时,可进行手动下降,将电动机尾端制动电 磁铁手动释放拉手缓缓向外拉出,使吊笼缓慢地向下滑行,吊笼下滑时,不得超过额定运行速度,手动 下降必须由专业维修人员进行操纵。 十一、作业后,应将吊笼降到底层,各控制开关拨到零位切断电源,锁好开关箱,闭锁吊笼门和围 护门。 十二、现场补充交底内容: 交底人签字: 日 期: 接受人(全员)签字: 注:本交底一式三份,班组、交底人、资料保管员各一份。
分类:安全操作规程 行业:其它行业 文件类型:Word 文件大小:44 KB 时间:2025-11-15 价格:¥2.00
施放气球企业安全生产执法检查表 项目 检查内容 检查 方法 检查依据 处罚依据 处罚标准 1.建立、健全本单位施放气球安 全生产责任制; 查看资料 现场检查 2.组织制定本单位施放气球安全 生产规章制度和操作规程; 查看资料 现场检查 3.组织制定并实施本单位施放气 球安全生产教育和培训计划; 查看资料 现场检查 4.保证本单位施放气球安全生产 投入的有效实施; 查看资料 现场检查 5.督促、检查本单位施放气球的 安全生产工作,及时消除生产安 全事故隐患; 查看资料 现场检查 一、 主要 负责 人履 职情 况 6.组织制定并实施本单位施放气 球的生产安全事故应急救援预案; 查看资料 《安全生产法》第 十八条 《安全生产法》第 九十一条 生产经营单位的主要负责人未履行安全生产管理 职责,未发生生产安全事故的,责令限期改正;逾期未 改正的,按以下标准处以罚款,并责令生产经营单位停 产停业整顿。 1. 未履行 1 项法定安全生产管理职责的,处 2 万 元以上 3 万元以下的罚款; 2. 未履行 2-3 项法定安全生产管理职责的,处 3 万元以上 4 万元以下的罚款 3. 未履行 4-7 项法定安全生产管理职责的,处 4 万元以上 5 万元以下的罚款。 现场检查 7.及时、如实报告施放气球生产 安全事故。 查看资料 现场检查 1.按规定取得施放气球资质证且 在有效期内。 查看资料 现场检查 1. 《施放气球管 理办法》第六条、 第十一条 1.《施放气球管理 办法》第二十七条 违反本办法规定: 1.未取得施放气球资质证从事施放气球活动,由县 级以上气象主管机构按照权限责令停止违法行为,处 1 万元以上 3 万元以下罚款; 2.给他人造成损失的,依法承担赔偿责任; 3.构成犯罪的,依法追究刑事责任。 二、 企业 资质 管理 2.验证施放气球资质条件、作业 人员符合规定数量。 查看资料 现场检查 《施放气球管理 办法》第七条、第 二十二条 1. 《施放气球管 理办法》第二十 九条 违反本办法规定,有下列行为之一的,由县级以上 气象主管机构按照权限责令改正,给予警告,可以处 1 万元以下罚款;情节严重的,处 1 万元以上 3 万元以下 罚款;造成重大事故或者严重后果的,依照刑法关于重 大责任事故罪或者其他罪的规定,依法追究刑事责任: (二)违反施放气球技术规范和标准的; 三、 安全 生产 1.施放气球单位应当按国家规定 保证施放气球安全生产所必需的 资金投入。 查看文件 现场检查 《安全生产法》第 二十条第一款 《安全生产法》第 九十条 生产经营单位的决策机构、主要负责人或者个人经 营的投资人不依照本法规定保证安全生产所必需的资 金投入,致使生产经营单位不具备安全生产条件的,责 令限期改正,提供必需的资金;逾期未改正的,责令生
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:33.8 KB 时间:2025-11-20 价格:¥2.00
检维修风险分析记录表 分析人员: 分析日期: 年 月 日 落实人: 验收人: 落实日期: 年 月 日 序 号 工作 项目 危险、危害因素 主要后果 现有控制措施(管理、技术) 可能性 L 值 严重性 S 值 风险度 R 值 落实 结果 1 动火作业 1、用火设备内未清理干净。 2、与用火设备相连的管线未 断开。 3、用火点周围有易燃物。 4、高处作业火花四溅。 5、用火点周围下水道、地沟 有易燃物。 6、乙炔气瓶卧放,且间距不 够 7、用火现场消防器材不符合 要求。 8、动火前未办理动火证。 火灾 人身伤害 1、 利用蒸煮、吹扫、置换或水洗等措施清 理干净用火设备内部构件,达到用火条件。 2、 断开管线,加盲板。 3、 用火前,清除周围易燃物。 4、 高处作业采取防火花飞溅措施。 5、 清除用火点周围下水道、地沟易燃物并 采取冲水、铺盖等手段进行隔离。 6、 乙炔气瓶禁止卧放,氧气瓶与火源及乙 炔气瓶间距不得少于 10 米。 7、 现场配备合适灭火器器材。 8、 立即办理动火手续。 2 3 6 检维修单位: 负责人: 检维修风险分析记录表 分析人员: 分析日期: 年 月 日 落实人: 验收人: 落实日期: 年 月 日 序 号 工作 项目 危险、危害因素 主要 后果 现有控制措施(管理、技术) 可能性 L 值 严重性 S 值 风险度 R 值 落实 结果 2 进入 受限 空间 作业 1、作业前未进行危险性分析。 2、没有对所有与受限空间相 连的阀门、管线加盲板。 3、设备未处理。 4、设备内通风不良。 5、设备上的转动设备未切断 电源。 6、受限空间进出口通道不畅。 7、盛装可燃有毒物质的设备 未分析。 8、作业人员不清楚设备内其 他危害因素。 9、作业现场没有监护措施。 10、未办理进罐证。 人身 伤害 1、作业前对进入受限容器进行危险性进行分析。 2、所有与受限空间相连的阀门、管线加盲板,列出盲 板清单,并落实到责任人。 3、对设备进行置换、吹扫、蒸煮。 4、设备打开通风孔、人孔等进行自然通风,温度适宜 人员作业,必要时采用强制通风或佩戴空气呼吸器。 但设备内缺氧时,严禁用通氧气的方法补充氧。 5、切断电源,挂“禁止合闸”标志,设专人监护。 6、清除进出口通道障碍物。 7、分析可燃、有毒有害物质含量。 8、对企业人员讲清楚设备内其他危害因素如附件等。 9、备齐消防、救生等器材。 10、立即办理进罐手续。 2 2 4
分类:风险评估 行业:其它行业 文件类型:Word 文件大小:69.5 KB 时间:2025-11-27 价格:¥2.00
安全生产、职业健康、环保责任书 甲方: (班组长) ,以下简称甲方 乙方: 徐和委 (班组工人) ,以下简称乙方 为进一步贯彻“安全第一,预防为主,综合治理”的安全生产方针,牢牢坚守“发 展决不能以牺牲人的生命为代价”红线,建立健全“党政同责、一岗双责、齐抓共 管”的安全监管基本框架,有效遏制职业健康、安全环保、安全生产责任事故发生, 结合本项目工程实际,特签订本责任书,以明确双方的责任和义务。 一、甲方责任清单 1、认真学习并贯彻执行项目有关安全生产的规章制度,以身作则,带头遵 守各项安全操作规程,及时纠正违章作业,对本工班(组)作业人员的生产安全 与健康负直接管理责任。 2、带领本工班(组)工人严格执行安全技术操作规程,遵守劳动纪律,听 从管理人员安全生产指导,制止“三违行为”,保证按正确方法施工;尤其对新工、 青工,更要加强安全教育和实际指导,必要时亲自示范。 3、认真执行安全技术交底制度,对不具备安全生产条件、人身安全得不到 保障的工程任务,有权拒绝施工,必要时可越级向上级领导或安监部门反映。 4、落实班前讲话活动,在班前对作业人员进行简明、实用的安全教育,提 高作业人员的安全意识,并将讲话现场录像,定期提交项目部安环部归档留存。 5、合理安排劳动力,严格控制加班、加点;根据当天的生产任务和每个工 人的思想动态、身体状况,具体布置其生产岗位,对不按时作息的人员要进行教 育,以保证其休息,避免事故发生.确保安全生产。 6、工作前必须先进入工地,对工地、工具、机电设备的安全情况进行检查, 坚持交接班制,发现问题及时解决,并将注意事项向本班组作业人员交待清楚; 保证本工班(组)的安全防护设施和个人劳动防护用品的正确使用。对不能解决 的问题,立即报告上级处理。 7、负责支持配备到工班(组)的兼职安全员工作,并发挥他们的作用。 8、自觉接受上级领导、有关方面和安监人员的安全监督检查,对检查中提 出的问题及时认真进行整改,不留隐患。 9、有权拒绝上级的违章指挥。遇有紧急险情,有权立即带领工人撤离现场, 并立即报告工地负责人及时组织排除险情。 10、对发现违章指挥、违章作业、违犯劳动纪律的“三违”行为不予制止及发 现事故隐患不予及时消除而导致的人身伤亡事故,承担直接领导责任。 11、积极参加抢险救灾活动。发生伤亡事故时要积极抢救伤员,保护现场, 并立即如实上报,组织本班组作业人员协助事故调查和分析工作。协助专职安全 生产监督管理员负责对未遂事故的分析、追查、处理。 12、因现场管理控制不严或不遵守安全生产相关文件要求而导致的人员伤 亡,建筑、车辆、机械损坏的,施工队伍须承担因此而发生的全部损失费用。 二、乙方责任清单 1、作业人员必须按照要求正确、完整地穿戴劳保防护用品。 2、认真贯彻执行安全生产的各项规章制度,提高安全生产意识,增强自我 防护意识,服从管理人员管理,及时纠正安全检查中发现的问题。 3、文明施工,不酒后上岗,不在施工现场吸烟,不随地乱扔垃圾。 4、施工中出现恶心、头晕、视野模糊等身体不适情况,必须立即停止工作。5、 应定期特别是起吊前要对以下部件进行检测: 1)电路线缆是否破损。 2)开关、刹车是否灵活可靠。 3)钢丝绳/吊带磨损程度是否需要更换 4)吊钩、保险扣是否能正常工作
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:26.6 KB 时间:2025-11-27 价格:¥2.00
对卫生计生服务机构安全生产检查清单 1.组织机构与人员情况 1.1 单位名称: 1.2 法定代表人: 1.3 分管领导: 1.4 电话、传真: 1.5 治安保卫部门: 1.6 负责人姓名、电话: 1.7 消防安全部门: 1.8 负责人姓名、电话: 1.9 后勤保障部门: 1.10 负责人姓名、电话: 1.11 医疗安全部门: 1.12 负责人姓名、电话: 1.13 治安保卫 编制内 人,编外人员 人 1.14 消防安全 编制内 人,编制外 人 1.15 后期保障 编制内 人,编外人员 人 1.16 医疗安全 编制内 人,编外人员 人 (备注: ) 2.制度建设基本情况 2.1 安全保卫制度 建立□ 种类数: 数量累计: 未建□ 2.2 消防安全制度 建立□ 种类数: 数量累计: 未建□ 2.3 医疗安全制度 建立□ 种类数: 数量累计: 未建□ 2.4 治安保卫岗位责任制 落实□ 否□ 2.5 责任书 签□ 否□ 2.6 消防岗位责任制 落实□ 否□ 2.7 责任书 签□ 否□ 2.8 后勤保障岗位责任制 落实□ 否□ 2.9 责任书 签□ 否□ 2.10 医疗安全岗位责任制 落实□ 否□ 2.11 责任书 签□ 否□ 2.12 治安保卫应急预案 制定□ 否□ 2.13 治安保卫资料 健全□ 否□ 2.14 后勤保障应急预案 制定□ 否□ 2.15 后勤保障资料 健全□ 否□ (备注: ) 3.治安保卫工作基本情况 3.1 单位行政值班管理情况 3.2 中控室管理情况 3.3 门卫、安全巡逻管理情况 3.4 应急队伍建立和演练情况 3.5 防恐防爆、处突措施落实情况 3.6 毒麻药品、放射源管理和防护情况 3.7 保安队伍管理情况 3.8 护工(包括临时人员)管理情况 (备注: ) 4.消防安全管理基本情况 4.1 消防设施配置及运行情况:经有资质的 专业单位按期检测 是□ 否□ 4.2 火灾报警、正压送风、排烟设施 有□ 无□ 4.3 灭火器材经有资质的专业单位按期检测 是□ 否□ 4.4 防火卷帘功能 正常□ 不正常□ 4.5 消防水泵压力符合标准 是□ 否□ 4.6 消防广播功能 正常□ 不正常□ 4.7 气体灭火设施功能正常 是□ 否□ 4.8 应急照明设施功能 正常□ 不正常□ 4.9 消防电梯运行 正常□ 不正常□ 4.10 消防通道畅通 是□ 否□ 4.11 疏散通道、安全出口畅通 是□ 否□ 4.12 食堂消防安全措施、灭火设备 有□ 无□ 4.13 集体宿舍消防安全措施 有□ 无□ 4.14 疏散标志 有□ 无□ 4.15 应急预案与演练 有□ 无□ 4.16 消防监控人员持证上岗 是□ 否□ 4.17 中控室值班记录 有□ 无□ 4.18 配电室值班记录 有□ 无□ 4.19 消防中控室报警主机主备电源 有□ 无□ 4.20 消防设施维护保养的记录 有□ 无□ 4.21 高层建筑防雷检测报告 有□ 无□ 4.22 电梯机房检测报告 有□ 无□ 4.23 病房报火警流程、防烟面具配备 4.24 建筑、装修履行施工场所
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:29.4 KB 时间:2025-12-01 价格:¥2.00
河南省焦化行业事故隐患自查清单----省工业和信息化委 Ⅰ级隐患自 查标准 Ⅱ级隐患自 查标准 Ⅲ级隐患 自查标准 Ⅳ级隐患 自查标准 自查标准项具体描述 参考依据 监管部门 营业执照 依法设立的公司,由公司登记机关发给公司营业执照。公司营业执照签 发日期为公司成立日期。 公司营业执照应当载明公司的名称、住所、注册资本、实收资本、经营 范围、法定代表人姓名等事项。 公司营业执照记载的事项发生变更的,公司应当依法办理变更登记,由 公司登记机关换发营业执照。 《公司法》 工商局 “三同时” 管理 新、改、扩建项目应履行安全设施“三同时”手续。 《建设项目安全设施“三同时”监督 管理暂行办法》 消防验收报 告 建设工程未经消防验收或者消防验收不合格的,禁止投入使用。 《消防法》 公安 主 要 负 责 人、安全生 产管理人员 资格 企业主要负责人、安全生产管理人员必须具备与本企业所从事的生产经 营活动相应的安全生产知识和能力。 《安全生产法》 基础管理 基础管理 资质证照 各类特种作 业人员的资 格证 企业的特种作业人员必须按照国家有关规定经专门的安全作业培训,取 得特种作业操作资格证书,方可上岗作业。 《安全生产法》 安监局 特种设备登 记证 锅炉、压力容器(含气瓶)、压力管道、电梯、起重机械和场(厂)内 专用机动车辆等特种设备在投入使用前或者投入使用后 30 日内,特种设备 使用单位应当向直辖市或者设区的市的特种设备安全监督管理部门登记。 《特种设备安全监察条例》 特种设备检 验报告 锅炉、压力容器(含气瓶)、压力管道、电梯、起重机械和场(厂)内 专用机动车辆等特种设备未经定期检验或者检验不合格的特种设备,不得 继续使用。 《特种设备安全监察条例》 应当对在用特种设备的安全附件、安全保护装置、测量调控装置及有关 附属仪器仪表进行定期校验、检修,并作出记录。 《特种设备安全监察条例》 质监局 工伤保险 用人单位应当按时缴纳工伤保险费。 《工伤保险条例》 资质证照 安全条件论 证和安全评 价 用于生产、储存危险物品的建设项目,应当按国家有关规定进行安全条 件论证和安全评价。 《安全生产法》 从业人员在三百人以上的应当设置安全生产管理机构或者配备专职安全 生产管理人员;从业人员在三百人以下的,应当配备专职或者兼职的安全 生产管理人员,或者委托具有国家规定的相关专业技术资格的工程技术人 员提供安全生产管理服务。 《安全生产法》
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:377 KB 时间:2025-12-16 价格:¥2.00
水利安全生产检查表 项目 检查内容 检查方法 检查依据 1.政府及行业主管部门安全生产工作文件贯彻落实 情况。 查看文件 资料 2.政府及行业主管部门安全生产会议精神贯彻落实 情况。 查看文件 资料 3.按要求及时上报安全生产信息、工作总结等材料。 查看文件 资料 一、 贯彻 落实 政府 安全 生产 工作 部署 4.重点时段安全生产检查情况。 查看检查 记录 1. 落实安全生产组织领导机构。项目法人成立由 各参建单位现场负责人组成的安全生产领导小组或 安全生产委员会;运行管理单位设立包括主要负责 人、部门负责人等相关人员参加的安全生产领导小 组或安全生产委员会,并以正式文件发布。 查看文件 资料 1.《企业安全生产责 任体系五落实五到位 规定》 2.《关于贯彻落实<国 务院关于坚持科学发 展安全发展 促进 安全生产形势持续稳 定好转的意见>进一 步加强水利安全生产 工作的实施意见》 二、 组织 机构 和职 责 2. 落实安全生产管理力量。依法设置安全生产管 理机构,配齐专业安全管理人员。施工单位按要求 配备施工现场专职安全生产管理人员。 查看文件 资料 1.《企业安全生产责 任体系五落实五到位 规定》 2.《水利工程建设安 全生产管理规定》 3.《安全生产法》第 二十条第一款 4.《河南省安全生产 条例》 5.《水利水电工程施 工 通 用 安 全 技 术 规 程》 3. 定期召开安全生产会议,研究部署相关工作。 查看文件 资料 1.《安全生产法》第 十八条 1.建立、健全本单位安全生产责任制,以及相关专 项岗位责任制,明确各岗位的责任人员、责任范围 和考核标准等内容。 查 看 安 全 生 产 责 任 制度 1.《安全生产法》第 十八条第一项、第十 九条 2.《水利水电工程施 工 通 用 安 全 技 术 规 程》 3.《水库大坝安全管 理条例》 4.《河南省水库安全 管理若干规定》 5.《危险化学品安全 管理条例》 三、 安全 生产 责任 制 2.明确安全生产目标,逐级签订安全生产责任书, 把安全生产工作情况列入考核内容。 查 看 安 全 生 产 责 任 书 1.《关于贯彻落实<国 务院关于坚持科学发 展安全发展 促进 安全生产形势持续稳 定好转的意见>进一 步加强水利安全生产 工作的实施意见》 1. 安全生产与本单位经济活动必须同时计划、部 署、检查、考核、总结。 查 看 安 全 生 产 工 作 文件 2.主要负责人将安全生产列入本单位重要议事日 程,定期召开会议,分析形势,研究解决安全生产 工作问题,依法组织开展检查。 查看会议、 检查记录 1.《安全生产法》第 十八条 四、 基础 管理 3.建立健全安全生产工作例会制度,安全教育培训 制度,安全生产检查制度,设备、设施及人员安全 查看文件 1.《安全生产法》第
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:38.1 KB 时间:2025-12-29 价格:¥2.00
框架填充墙砌筑工程技术交底 单位工程名称: 2002 年 月 日 工程名称 施工员 作业班组 施工部位 质监员 班组长 一、交底内容: 1、本工程采用轻质空心砖小型砌块和轻质矿蒸配套实心砖组砌。砌体容重必须<1000kg/m3。并有出 厂合格证和试验报告。 2、弹出轴线、墙边线,门窗洞口线,经复核无误。 3、在框架柱上画皮数杆,注明门窗洞口、木砖、过梁的尺寸标高。 4、根据最下面第一皮砖的标高拉通线检查,如水平灰缝厚度超过 20mm,用细石混凝土找平,不得 用混合砂浆找平或砍砖包合子找平。 5、砌筑前,基础顶面或楼面清扫干净,洒水湿润。 6、根据设计图纸各部位尺寸,排砖撂底,使组砌方法合理,便于操作。 7、砂浆配合比应用重量比,计量精度为,水泥±2%,砂及掺合料±5%。 8、砂浆拌合采用机械搅拌,投料顺序为砂——水泥——掺合料——水,搅拌时间不少于 1.5 分钟。 9、砂浆应随拌随用,水泥或水泥混合砂浆一般在拌合后 3~4 小时内用完,严禁用过夜砂浆。 10、组砌方法应正确,上、下错缝,交接处咬槎搭砌,掉角严重的空心砖不宜使用。 11、空心砖砌体水平灰缝应为 8~12mm,砂浆应饱满,平直通顺,立缝打提刀灰,并用砂浆填实。 12、空心砖墙在地面或楼面上先砌三皮实心砖,空心砖墙砌至梁或楼板下,应待墙体下沉稳定且砂浆 终凝后再用实心砖斜砌挤紧,并用砂浆填实。各种预留洞、预埋件等,应按设计要求设置,避免 后剔凿。转角及交接处同时砌筑,不得留直槎,斜槎高不大于 1.2m。 13、心砖墙门窗框两侧用实心砖砌筑,每边不少于 24cm。 14、当需在墙体中部上剔水平槽时,应根据线槽标高位置用轻质实心砖砌筑,以便剔槽。 15、拉通线砌筑时,随砌、随吊、随靠,保证墙体垂直、平整,不允许砸砖修墙。 16、蒸压加气砼砌块搭砌长度不应小于砌块长度的 1/3;轻骨料砼小型空心砌块搭砌长度不应小于 90mm;竖向通缝不应大于 2 皮。 17、砼墙柱内预埋拉结筋经常不能与砖行灰缝吻合,不应将拉结筋弯折使用。位置不对的拉结筋处可 用配套小砌块平砌进行调整。 二、补充交底内容: 接交底人员签名: 2002 年 月 日
分类:安全管理制度 行业:建筑加工行业 文件类型:Word 文件大小:23 KB 时间:2026-01-22 价格:¥2.00
中天建设集团有限公司 ★钢筋工程专项施工方案★ 第 1 页 共 23 页 目 录 一、编制依据 ............................................2 二、工程概况 ............................................2 三、钢筋场地的准备.......................................4 四、投入主要施工机具 .....................................4 五、作业条件 ............................................5 六、钢筋进场检验与验收要求................................5 七 、钢筋的储存 .........................................5 八 、钢筋的加工施工工艺 ..................................5 九 、钢筋的原材料及加工的质量要求..........................6 十 、钢筋焊接 ...........................................8 2)、直螺纹操作的施工工艺.................................9 十一、钢筋绑扎施工工艺 ..................................10 1)、底板钢筋绑扎 .......................................10 2)、柱钢筋绑扎 .........................................11 3)、地下室剪力墙钢筋绑扎 ................................12 4)、梁钢筋绑扎 .........................................14 5)、楼板钢筋绑扎 .......................................15 6)、楼梯钢筋绑扎 .......................................16 7)、钢筋安装及预留预埋 ..................................16 十二、钢筋连接、安装工程的质量要求........................16 十三、钢筋工程施工注意事项...............................18 十四、钢筋工程施工应注意的质量问题........................18 十五、钢筋工程施工主要安全技术措施........................20 十六、钢筋工程成品保护措施...............................20 十七、环境、职业健康安全管理措施..........................21 十八、成本降低措施......................................21 中天建设集团有限公司 ★钢筋工程专项施工方案★ 第 2 页 共 23 页 钢筋工程专项施工方案 一、编制依据 1、本工程的施工组织设计 2、根据我公司施工项目经验,安全可靠,满足工程需求且合理使用。 3、深圳市华阳国际工程设计有限公司提供的本工程的施工图纸。 4、施工中执行的规范、标准 1、混凝土结构工程质量验收规范(GB50204-2015) 2、高层建筑混凝土结构规程(JGJ3-2010) 3、混凝土结构整体平面表示法(11G101) 4、钢筋焊接及验收规程 (JGJ18-2012) 5、广州市创文明安全工地的有关文件 二、工程概况 序号 项 目 内 容 1 工程名称 广州花都雅展房地产开发有限公司 住宅楼(自编号 33-38 座) 及地下室 2 工程地址 广州市花都区花山镇 106 国道以东 3 建设单位 广州花都雅展房地产开发有限公司 4 监理单位 广州联嘉建设监理有限公司 5 设计单位 深圳市华阳国际工程设计有限公司 6 勘察单位 广州市建筑科学研究院新技术开发中心有限公司 7 施工单位 中天建设集团有限公司 8 投资性质 自筹资金 9 工期目标 日历 730 天 10 质量目标 合格工程、争创市、省优良样板工程 1、建筑设计概况 建筑面积 约 72323.2m2 建筑用途 住宅 建筑防火等级 住宅楼:二级 建筑特点 单元式住宅 建筑总高度 43.45m 地上层数 15 层 地下层数 2 层 地上标准层高度 2.8m
分类:安全管理制度 行业:建筑加工行业 文件类型:Word 文件大小:4.7 MB 时间:2026-01-23 价格:¥2.00
中天建设集团有限公司 ★防水、防渗漏专项施工方案★ 第 0 页 共 21 页 目录 第一章 编制依据 ...................................................................................................................1 第二章 工程概况 ...................................................................................................................1 第三章 设计概况 ...................................................................................................................3 一、地下室防水做法.................................................................................................................3 二、屋面防水做法:.................................................................................................................4 三、楼面防水做法:.................................................................................................................4 四、外墙防水做法:.................................................................................................................5 五、内墙防水做法:.................................................................................................................5 第四章 防水材料 ...................................................................................................................5 一、防水材料选用:..........................................................................................................5 二、产品特点:........................................................................................................................5 三、地下室防水工程: ......................................................................................................5 第五章 地下室及屋面防水施工方法 .....................................................................................6 一、聚氨酯防水涂膜.................................................................................................................6 二、40 厚细石砼刚性防水层....................................................................................................9 三、高聚物改性沥青防水卷材(聚酯胎) ................................................................................13 第六章 铝窗安装防水渗水施工方法 ...................................................................................16 一、做好铝合金门窗安装的准备工作...................................................................................16 二、铝合金门窗的安装...........................................................................................................17 三、土建配合施工内容...........................................................................................................17 四、铝合金门窗渗漏水防治措施...........................................................................................18 第七章 卫生间防水渗水施工 ..............................................................................................19 一、卫生间防水施工的准备工作:.......................................................................................19 二、工艺流程:.......................................................................................................................19 三、施工操作工艺...................................................................................................................19 四、注意事项:.......................................................................................................................20 中天建设集团有限公司 ★防水、防渗漏专项施工方案★ 第 1 页 共 21 页 第一章 编制依据 1、本工程的施工组织设计 2、根据我公司施工项目经验,安全可靠,满足工程需求且合理使用。 3、深圳市华阳国际工程设计有限公司提供的施工图纸 3、国家相关标准和规程: (1)GB50300-2013 建筑工程施工质量验收统一标准; (2)GB50208-2011 地下防水工程质量验收规范; (3)GB50207-2012 屋面工程质量验收规范; (4)DBJ15—19-2006 建筑防水工程技术规程; (5)广州市创文明安全工地的有关文件 第二章 工程概况 一、 工程概况 序号 项 目 内 容 1 工程名称 广州花都雅展房地产开发有限公司 住宅楼(自编号 33-38 座) 及地下室 2 工程地址 广州市花都区花山镇 106 国道以东 3 建设单位 广州花都雅展房地产开发有限公司 4 监理单位 广州联嘉建设监理有限公司 5 设计单位 深圳市华阳国际工程设计有限公司 6 勘察单位 广州市建筑科学研究院新技术开发中心有限公司 7 施工单位 中天建设集团有限公司 8 投资性质 自筹资金 9 工期目标 日历 730 天 10 质量目标 合格工程、争创市、省优良样板工程 1、建筑设计概况 建筑面积 约 72323.2m2 建筑用途 住宅 建筑防火等级 住宅楼:二级 建筑特点 单元式住宅 建筑总高度 43.45m 地上层数 15 层 地下层数 2 层
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:179 KB 时间:2026-01-24 价格:¥2.00
中天建设集团有限公司 ★ 外墙淋水试验实施方案★ 第 1 页 共 10 页 目 录 一、编制依据 ..................................................................................................................................................2 二、工程概况 ..................................................................................................................................................2 2.1、工程总体概况 ................................................................................................................................3 2.2、建筑设计概况 ................................................................................................................................3 2.3、建筑外立面设计概况 ....................................................................................................................3 三、施工部署(安排) ..................................................................................................................................3 3.1、外墙淋水的部位及淋水范围 ........................................................................................................4 3.2、外墙淋水试验实施的时间 ............................................................................................................4 3.3、劳动力组织与职责分工 ................................................................................................................4 四、施工准备 ..................................................................................................................................................5 4.1、技术准备 ........................................................................................................................................5 4.2、材料计划 ........................................................................................................................................5 4.3、施工机具计划 ................................................................................................................................5 4.4、劳动力计划 ....................................................................................................................................6 五、主要施工方法和施工要点 ......................................................................................................................6 5.1、布管和淋水一般要求 ....................................................................................................................6 5.3 外墙淋水试验记录和问题处理 .......................................................................................................7 六、淋水试验质量要求 ..................................................................................................................................7 七、成品保护 ..................................................................................................................................................8 7.1、淋水用水 ........................................................................................................................................8 7.2 外墙饰面砖及铝合金窗 ...................................................................................................................8 八、安全文明施工保证措施 ..........................................................................................................................8 7.1、组织措施 ........................................................................................................................................8 7.2、安全技术措施 ................................................................................................................................8 7.3、文明施工措施 ................................................................................................................................9 九、环保及职业健康安全管理措施 ..............................................................................................................9 中天建设集团有限公司 ★ 外墙淋水试验实施方案★ 第 2 页 共 10 页 外墙淋水试验实施方案 一、编制依据 为了保证花山万科热橙四组团外墙外立面防水效果,满足业主入住使用功能,不断 提高建设工程施工质量、有效解决住宅工程外墙渗水质量通病;贯彻政府文件要求,参 照东莞市住房和城乡建设局 2013 年 1 月 17 日下发《关于在我市开展住宅工程装饰装修 分部验收前外墙淋水试验的通知》(编号:东建质安[2013]7 号)文件要求。本工程特按 照工程特点,依据设计施工图纸、技术文件,按照现行施工验收规范、技术操作规程、 国家质量检验标准、国家法令法规、政府有关文件精神,结合本工程质量标准、采用外 墙淋水检查的手段,加强外墙渗水质量缺陷控制,特编制本外墙淋水试验实施方案。 编制本方案依据的施工图纸、施工组织设计、规范及标准详见表式 1.1: 表式 1.1 编制依据表 序号 类别 名 称 编 号 1 图纸 花山万科热橙四组团土建及安装工程设计施工图纸及 相关设计文件(包括设计变更、图纸会审记录、设计交 底等) / 2 施组 《花山万科热橙四组团土建及安装工程施工组织设计》 / 3 方案 《花山万科热橙四组团土建及安装工程施工方案》 / 4 国标 《建筑工程施工质量验收统一标准》 GB50300-2013 5 地方要求 《广东省住宅工程质量通病防治二十条》 / 6 公司内部 《施工方案编制审核管理办法》 建技〔2010〕12 号
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:117 KB 时间:2026-01-30 价格:¥2.00
施工升降机操作安全技术交底 GDAQ330605 施工单位: 工程名称 分部分项 工 程 工种 一、进入施工现场必须遵守安全操作规程和安全生产纪律,操作工人必须取得省级建设主管部门颁 发的建筑施工特种作业人员操作证书,方可上岗。 二、施工升降机运行作业前重点检查项目(每天检查内容)应符合下列要求: (一)各部结构无变形,连接螺栓无松动; (二)齿条与齿轮、导向轮与导轨均接合正常; (三)各部钢丝绳固定良好,无异常磨损; (四)检查电缆导向上下,安全保护开关以及电磁制动器是否灵敏可靠。 (五)在传动机械运转时是否有噪声以及有异常声响。 (六)门的开启关闭电锁状况是否良好。 (七)运行范围内无障碍。 (八)仔细阅读上一班司机写的运转记录,以便了解机械状况。 三、启动前,应检查并确认电缆、接地线完整无损,控制开关在零位。电源接通后,应检查并确认 电压正常,应测试无漏电现象。应试验并确认各限位装置、吊笼、围护门等处的电器联锁装置良好可靠, 电器仪表灵敏有效。启动后,应进行空载升降试验 测定各传动机构制动器的效能,确认正常后,方可开 始作业。 四、升降机在每班首次载重运行时,当吊笼升离地面 1~2m 时,应停机试验制动器的可靠性;当发 现制动效果不良时,应调整或修复后方可运行。 五、吊笼内乘人或载物时,应使载荷均匀分布,不得偏重严禁超载运行。 六、操作人员应根据信号操作,作业前应鸣声示意在升降机未切断总电源开关前,操作人员不得离 开操作岗位。 七、当升降机运行中发现有异常情况时,应立即停机并采取有效措施将吊笼降到底层,排除故障后 方可继续运行。在运行中发现电气失控时,应立即按下急停按钮,在未排除故障前,不得打开急停按钮。 八、升降机在大雨、大雾、六级及以上大风以及导轨架、电缆等结冰时、必须停止运行,并将吊笼 降到底层切断电源暴风雨后,应对升降机各有关安全装置进行一次检查,确认正常后,方可运行。 九、升降机运行到最上层或最下层时,严禁用行程限位开关作为停止运行的控制开关。 十、当升降机在运行中由于断电或其他原因而中途停止时,可进行手动下降,将电动机尾端制动电 磁铁手动释放拉手缓缓向外拉出,使吊笼缓慢地向下滑行,吊笼下滑时,不得超过额定运行速度,手动 下降必须由专业维修人员进行操纵。 十一、作业后,应将吊笼降到底层,各控制开关拨到零位切断电源,锁好开关箱,闭锁吊笼门和围 护门。 十二、现场补充交底内容: 交底人签字: 日 期: 接受人(全员)签字: 注:本交底一式三份,班组、交底人、资料保管员各一份。
分类:安全操作规程 行业:其它行业 文件类型:Word 文件大小:43 KB 时间:2026-01-31 价格:¥2.00
中天建设集团有限公司 ★安全生产专项施工方案★ 第 1 页 共 25 页 目 录 第一章:工程概况…………………………………………………………3 第二章:安全生产目标管理…………………………………………… 4 第一节:安全生产目标………………………………………………4 第二节:安全生产管理………………………………………………4 第三章:安全保证体系………………………………………………… 5 第一节:安全文明领导小组体系……………………………………5 第二节:目标责任分解………………………………………………6 第四章:安全生产具体措施 ………………………………………… 7 第一节:安全管理制度………………………………………………7 第二节:分项工程安全管理措施……………………………………9 第三节:脚手架安全使用技术措施…………………………………15 第五章:“三宝”“四口”安全保护措施 ………………………… 17 第六章:施工用电…………………………………………………………19 第一节:支线架设……………………………………………………19 第二节:现场照明……………………………………………………19 第三节:架空线………………………………………………………20 第四节:电箱(配电箱、开关箱)……………………………… 20 第五节:接地接零………………………………………………… 21 第六节:变配电装置 …………………………………………… 21 第七章:中小型机具………………………………………………………… 16 第八章:防火安全…………………………………………………………… 17 第九章:文明施工控制措施 ………………………………………… 18 第一节:原则 …………………………………………………… 18.. 第二节:施工现场布置………………………………………………18 第三节:现场围墙……………………………………………………19 第四节:封闭管理 …………………………………………………19 第五节:施工场地……………………………………………………19 第六节:现场住宿……………………………………………………20 第七节:材料堆放……………………………………………………20 第八节:治安综合治理………………………………………………20 第九节:生活卫生……………………………………………………21 第十节:保健急救……………………………………………………21 第十一节:社区服务…………………………………………………21 第十二节:施工防护…………………………………………………21 附图…………………………………………………22 中天建设集团有限公司 ★安全生产专项施工方案★ 第 2 页 共 25 页 第一章 工程概况 工程概况 序号 项 目 内 容 1 工程名称 广州花都雅展房地产开发有限公司 住宅楼(自编号 29-30 座)、 住宅楼(自编号 31-32 座)、住宅楼(自编号 39-40 座)、住宅楼(自 编号 41-42 座)、住宅楼(自编号 33-38 座)及地下室 2 工程地址 广州市花都区花山镇 106 国道以东 3 建设单位 广州花都雅展房地产开发有限公司 4 监理单位 广州联嘉建设监理有限公司 5 设计单位 深圳市华阳国际工程设计有限公司 6 施工单位 中天建设集团有限公司 7 投资性质 自筹资金,按形象进度拨款 8 工期目标 730 日历天 9 质量目标 合格工程、争创市、省优良示范工程 1、建筑设计概况 建筑面积 约 86282.8m2 建筑用途 住宅、车库、人防 建筑防火等级 住宅楼:二级 地下室:一级 建筑特点 单元式住宅、地下停车 库 建筑防水等级 一级 建筑总高度 42.55 地上层数 15 层 地下层数 2 层 地上标准层高度 2.8m 地下层高 3.5m、3.6m 设计使用年限 50 年 2、 结构设计概况 基础结构型式 预应力高强砼管桩基础 主体结构型式 钢筋混凝土框架剪力墙结构 结 构 型 式 屋面结构型式 钢筋混凝土梁板结构 地下室底板(含桩 承台、基础梁) C30(P6) 柱 C35、C30(P6) 砼强度等级 梁、板 C30 抗震等级 工程设防烈度 6 度 HPB235 - HRB335 - 钢筋类别 HRB400 6、8、10、12、14、16、18、20、22、25 等
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:230 KB 时间:2026-02-12 价格:¥2.00
中天建设集团有限公司 ★ 外墙淋水试验实施方案★ 第 1 页 共 10 页 目 录 一、编制依据 ..................................................................................................................................................2 二、工程概况 ..................................................................................................................................................3 2.1、工程总体概况 ................................................................................................................................3 2.2、建筑设计概况 ................................................................................................................................3 2.3、建筑外立面设计概况 ....................................................................................................................3 三、施工部署(安排) ..................................................................................................................................3 3.1、外墙淋水的部位及淋水范围 ........................................................................................................4 3.2、外墙淋水试验实施的时间 ............................................................................................................4 3.3、劳动力组织与职责分工 ................................................................................................................5 四、施工准备 ..................................................................................................................................................5 4.1、技术准备 ........................................................................................................................................5 4.2、材料计划 ........................................................................................................................................5 4.3、施工机具计划 ................................................................................................................................5 4.4、劳动力计划 ....................................................................................................................................6 五、主要施工方法和施工要点 ......................................................................................................................6 5.1、布管和淋水一般要求 ....................................................................................................................6 5.3 外墙淋水试验记录和问题处理 .......................................................................................................7 六、淋水试验质量要求 ..................................................................................................................................7 七、成品保护 ..................................................................................................................................................8 7.1、淋水用水 ........................................................................................................................................8 7.2 外墙饰面砖及铝合金窗 ...................................................................................................................8 八、安全文明施工保证措施 ..........................................................................................................................8 7.1、组织措施 ........................................................................................................................................8 7.2、安全技术措施 ................................................................................................................................8 7.3、文明施工措施 ................................................................................................................................9 九、环保及职业健康安全管理措施 ..............................................................................................................9 中天建设集团有限公司 ★ 外墙淋水试验实施方案★ 第 2 页 共 10 页 外墙淋水试验实施方案 一、编制依据 为了保证花山万科热橙四组团外墙外立面防水效果,满足业主入住使用功能,不断 提高建设工程施工质量、有效解决住宅工程外墙渗水质量通病;贯彻政府文件要求,参 照东莞市住房和城乡建设局 2013 年 1 月 17 日下发《关于在我市开展住宅工程装饰装修 分部验收前外墙淋水试验的通知》(编号:东建质安[2013]7 号)文件要求。本工程特按 照工程特点,依据设计施工图纸、技术文件,按照现行施工验收规范、技术操作规程、 国家质量检验标准、国家法令法规、政府有关文件精神,结合本工程质量标准、采用外 墙淋水检查的手段,加强外墙渗水质量缺陷控制,特编制本外墙淋水试验实施方案。 编制本方案依据的施工图纸、施工组织设计、规范及标准详见表式 1.1: 表式 1.1 编制依据表 序号 类别 名 称 编 号 1 图纸 花山万科热橙四组团土建及安装工程设计施工图纸及 相关设计文件(包括设计变更、图纸会审记录、设计交 底等) / 2 施组 《花山万科热橙四组团土建及安装工程施工组织设计》 / 3 方案 《花山万科热橙四组团土建及安装工程施工方案》 / 4 国标 《建筑工程施工质量验收统一标准》 GB50300-2013 5 地方要求 《广东省住宅工程质量通病防治二十条》 / 6 公司内部 《施工方案编制审核管理办法》 建技〔2010〕12 号
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:118 KB 时间:2026-02-20 价格:¥2.00
电气安装工程技术交底 工程名称 施工员 作业班组 施工部位 质监员 班组负责人 一、交底内容: ⑴、线管敷设:主要采用金属管和 PVC 塑料管两种材料,其中金属钢管使用在楼梯照明、方向指示灯和消防 系统控制部分,一般照明、共用天线、电话通讯使用 PVC 塑料管。预埋线管的弯曲半径要≥10d,钢管采用丝扣 连接,并做跨接焊作为保护接地,PVC 塑料管采用套管胶粘剂连接。 ⑵、电缆敷设:先根据设计要求,画出电缆排列图,尽量避免互相交叉,敷设时应防止扭伤和过分弯曲,竖 井内敷设电缆时,由上向下施工,以免电缆受过大的机械拉力,穿过墙洞或楼板时,均应套上合适的保护套管, 电缆与套管间应用防火材料密实,以满足消防要求。电缆的标牌要用尼龙带扎牢,标牌上应标明回路编号、电缆 规格、长度和终端设备编号。电缆头制作完毕后,要进行复测,其线间绝缘电阻值,应大于 10MΩ。 ⑶、管内穿线:各回路导线的颜色统一规定为:红(火)、黑(0)、双色(PE)。待土建粗装结束后,开始进 行穿线,管内导线的总截面不应超过管内截面的 60%,穿线前要检查管口是否光滑,有无毛刺,要求护口齐全, 管道畅通,导线型号符合设计要求。同一管内不同系统、不同电压、不同电流类别的导线,不允许穿在同一根管 内。穿线后还要测量线间绝缘电阻,其线间绝缘电阻值应大于 0.5 MΩ,并做好隐蔽记录,才能接入用电器具。 ⑷、开关、插座、灯具的安装:开关、插座应严格按设计标高进行施工,同室同一水平标高,偏差不应大于 5mm, 成排安装的不应大于 2mm,插座一律按左零、右相、上端 PE。开关一律上开、下关,并控制火线回路。同一室内 的成排灯具,安装前应放线,以保横竖成排,中心对齐,安装后其中心偏差不大于 5mm。 ⑸、户内配电箱盒安装:配电箱盒一般都安装在分户门内侧,箱底距地面高度为 1.7m,内配备插座回路的漏 电开关,照明回路的限额电流开关。箱体、箱盖应与接地支干线连接,要求所有回路的 PE 线和零线分别接到各 自的汇流端子上,安装完毕后,对各回路分别作一次检测,然后才能通电,并做漏电试验,检验配电开关的灵敏 度,做好又验收记录。 二、补充内容: 接受交底人员签名: 2002 年 月 日
分类:安全管理制度 行业:建筑加工行业 文件类型:Word 文件大小:22 KB 时间:2026-03-14 价格:¥2.00
1 6S 教育训练资料(一) 一、 6S 的由来 5S 最先从日本提出,1955 年日本针对地、物提出整理、整顿 2S,后来因管理水准的提升才陆续增加了其余的 3S,从而形成了 目前广泛推行的 5S 架构,现在还有很多企业提出了 6S、7S、8S。 根据我厂的实际和需要,增加安全,即现在我们要推行的 6S。 二、 什么叫 6S 定义:6S 是目前企业广泛推祟的一种管理方法,它的主 要构成按先后顺序是:整理、整顿、清扫、清洁、素养、安全。 此 6 项内容在日文的罗马发音中均以 S 开头,所以叫 6S。 2.1 整理(SEIRI) 就是把要与不要的东西加以区分,工作场所中不要的东西一律不 得放置。——提高效率的开始。 2.2 整顿(SETTON) 就是把所需要的东西以最简便的方式放好,即定位,使大家一目 了然——免除寻找的浪费。 2.3 清扫(SEISO) 就是随时维持工作场所无脏污,并防止污染的发生,使缺点显现 出来——提高品质的基础。 2.4 清洁(SEIKETSU) 将前 3S 做到制度化、规范化,并维持其成果——安全的第一步 2 2.5 素养(SHILSUKE) 人人依规定办事,养成良好习惯 2.6 安全(Safety) 预防为主,加强安全防范,确保安全无事故 三、 推行 6S 的意义 3.1 企业方面 3.1.1 提升品质,降低不良 3.1.2 减少浪费,降低成本 3.1.3 确保交期,顺利交货 3.1.4 安全有保障,工厂无伤害 3.2 个人方面 3.2.1 个人仪容仪表整洁 3.2.2 言谈举止文明 3.2.3 规章制度的遵守 3.2.4 思想道德与修养的提升 3.3 家庭方面 3.3.1 生活用品的区分 3.3.2 喜庆日子的布置 3.3.3 邻里关系的处理
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:56 KB 时间:2026-03-16 价格:¥2.00
附件 1: 游乐园管理规定 (修订征求意见稿) 第一章 总则 第一条 为了加强游乐园管理,保障游乐园安全运营,制定本 规定。 第二条 游乐园的规划、建设、运营和管理适用本规定。 第三条 本规定所称游乐园包括: (一)在独立区域以游乐设施开展游乐活动的经营性场所; (二)在公园内设有游乐设施的场所。 本规定所称的游乐设施,是指在特定的区域内运行,承载游客游 乐的载体。广义上除可包括具有动力的游乐器械外,还包括为游乐而 设置的构筑物和其他附属装置以及无动力的游乐载体。 本规定所称的大型游乐设施,是指用于经营目的,承载乘客游乐 的设施,其范围规定为设计最大运行线速度大于或者等于 2m/s, 或者运行高度距地面高于或者等于 2m 的载人游乐设施。 第四条 住房和城乡建设部负责全国游乐园的规划、建设和管 理工作;国家质量监督检验检疫总局负责全国大型游乐设施的质量监 督和安全监察工作。 县级以上地方人民政府园林、质量技术监督行政部门,负责本行政区 域内相应的工作。 第二章 规划与建设 第五条 游乐园的规划、建设应当符合城市规划,统筹安排。 第六条 需要新建游乐园的,应当对建设地点、资金、游乐设施、 管理技术条件、人员配备等方面,进行综合分析论证,提出可行性报 告和计划任务书,并向城市人民政府规划园林行政主管部门提出申 请。 城市人民政府规划行政主管部门审批前,应当征得城市人民政府 园林行政主管部门同意。 城市人民政府园林行政主管部门应当对 新建游乐园组织论证,广泛征求社会各界意见,论证结构应当公示。 第八条 以室外游乐设施为主的游乐园,绿地(水面)面积应 当达到全园总面积的 60%以上。 游乐园经营单位应当加强国内绿地的美化和管理,搞好绿地和园 林植物的维护。 第九条 在游乐园内服务设施的设置应当符合游乐园规划设计 方案。 任何单位和个人不得擅自在游乐园内摆摊设点。 第十条 城市人民政府规划行政主管部门在游乐园规划审批 时,应当将游乐园规划设计方案征求城市人民政府园林行政主管部门 的意见。 游乐园规划设计方案,应当由城市人民政府园林行政主管部门组 织论证,广泛征求社会各界意见,论证结构应当公示。 游乐园应当按照批准的规划设计方案进行建设。改变游乐园规划
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:22.5 KB 时间:2026-03-22 价格:¥2.00
职业病危害(职业卫生)检测评价人员复习题 一、填空(每空 0.5 分,共 25 分): 1、生产经营单位应当加强作业场所的职业危害防治工作,为从业人员提供符合法 律、法规、规章和国家标准、行业标准的 工作环境 ,采取有效措施,保障 从业 人员 的职业健康。 2、 生产经营单位 是职业危害防治的责任主体。 3、职业危害,是指从业人员在从事职业活动中,由于接触 粉尘 、放射 性 、 有毒化学物质 、物理 等有害因素而对 身体健康 所造成的各种损 害。 4、生产经营单位应当为 存在劳动关系的劳动者 建立职业健康监护档案,并按 照规定的期限妥善保存。 5、厂区总平面布置:生产区宜选在大气污染物 扩散条件好 的地段。 6、高温、热加工、有特殊要求和人员较多的建筑物应避免 西晒 。 7、当机械通风系统采用部分循环空气时,送入工作场所空气中有害气体、蒸汽及 粉尘的含量,不不应超过规定接触限值的 3% 。 8、夏季自然通风的进气窗其下端距地面不应高于 1.2m ,以便空气直接吹向 工作地点。冬季自然通风用的进气窗其下端一般不低于 4m 。如低于 4m 时,应 采取防止冷风吹向工作地点的有效措施。 9 、 当 工 作 地 点 气 温 ≥ 3 5 ℃ 时 , 应 采 取 局 部 降 温 和 综合 防暑 措施,并应减少接触时间。 10、浴室、盥洗室厕所的设计,一般按劳动者 最多的班组人数 人数设计,存衣室 设计计算人数应按 车间劳动者实际人数 计算。 11、生产或使用剧毒或高毒物质的高风险工业企业应设置 紧急救援站 或 有毒气体防护站 。 12、在《工作场所化学物质容许浓度》备注栏中,标有“皮”及“G1”字样,“皮” 指 因皮肤、黏膜和眼睛直接接触蒸气、液体和固体,通过完整的皮肤吸收引起全身效 应“G1”指 确认人类致癌物 。 13、高温危害评价中接触时间率是指:劳动者在一个工作日内实际接触高温作业的 累计时间 和 8h 的比率。 14、手传振动的测量,按照 生物力学 坐标系,分别测量三个轴向振动的 频率 计权加速度值 ,取 三个轴向的最大值 作为被测工具或工件的手传振动值。 15、煤矿井下的主要支护方式有 锚杆(锚锁)同喷支护、 支架支护 、砌碹支护、工 字钢支护和坑木支护。 16、定点采样采样点的选择应选择 有代表性的 工作地点,其中应包括有 害物质 浓度最高 、劳动者 接触时间最长 的工作地点。 17、噪声的测量:工作场所声场分布不均匀时,应将其划分若干声级区,同一声级 区内 声级差<3dB(A) 。每个区域内,选择 2-3 个测点,取平均值。 1 8 、 一 个 有 代 表 性 的 工 作 场 所 内 有 多 台 同 类 生 产 设 备 时 , 1-3 台设置 1 个采样点, 4-10 台设置 2 个采样点; 10 以上,至少设置 3 个采样点。 19、高温的测量:常年从事高温作业,在夏季最热季节 测量,不定期 从事高温作业,在 工期内最热月 测量;从事室外作业,在最热月晴天有太阳辐射时 测量。 二、判断题(每题 0.5 分,共 15 分) 1、作业场所使用有毒物品的生产经营单位,应当按照有关规定向安全生产监督管理部 门申请办理职业卫生安全许可证。 ( √ ) 2、从事易燃易爆作业的人员应穿含金属纤维的棉布工作服,以防静电危害。(√ ) 3、减少环境中尘毒的根本办法是戴防毒面具。(×) 4、对接触职业危害的从业人员,生产经营单位应当按照国家有关规定组织上岗前、在 岗期间和离岗时的职业健康检查,并将检查结果如实告知从业人员。职业健康检查费用 由生产经营单位及从业人员共同承担。 ( × ) 5、生产经营单位应当依法为从业人员办理工伤保险,缴纳保险费。 ( √ ) 6、工业企业选址应避开自然疫源地,对因建设工程需要不能避开的,不需采取相应的 措施。 ( × ) 7、在同一工业区内布置不同卫生特征的工业企业时,宜避免不同有害因素产生交叉污 染就可以。 ( × ) 8、 《 职 业 病 目 录 》 中 , 尘 肺 指 包 含 矽 肺 及 金 属 尘 肺 在 内 的 13 种 尘 肺 。 ( √ ) 9、 生 产 经 营 单 位 不 得 安 排 有 职 业 禁 忌 的 劳 动 者 从 事 有 毒 物 品 作 业 。 ( √ ) 10、GBZ2.2-2007 中所规定的采掘工作场所气象条件的标准适用于包括煤矿在内的所有 井下采掘作业。 ( × ) 11、有可能泄漏液态剧毒物质的高风险作业场所,应专设泄险渠等应急设施。 ( √ ) 12、煤矿采煤司机及助手作业时粉尘采样点应布置在距工人操作处 1.5m 下风侧。 ( √ ) 13、 特 殊 高 温 作 业 , 热 辐 射 强 度 应 小 于 700W/m2, 室 内 气 温 不 应 超 过 26℃ 。 ( × ) 14、 噪 声 与 振 动 较 大 的 生 产 设 备 应 安 装 在 单 层 厂 房 或 多 层 厂 房 的 底 层 。 ( √ ) 15、遇湿易燃物品可以露天储存。(×) 16、建设项目职业病危害控制效果评价在评价阶段应完成的工作是:工程分析、职业卫 生调查、职业病危害因素定性定量分析与评价。 ( √ ) 17、指令性标识的背景色为蓝色,标示图及外圈均为白色,安全色至少要覆盖总面积的 50%。 18、 噪 声 检 测 声 级 计 的 要 求 为 : 2 型 及 以 上 , 具 有 A 计 权 及 S 档 。 ( √ ) 19、 紫 外 线 的 测 量 应 测 量 操 作 人 员 面 、 眼 、 肢 体 及 其 它 暴 露 部 位 。 ( √ ) 20、煤矿井下凿岩工采样位置设在距工作面 3-7m 的回风侧。( × ) 21、 国 家 标 准 中 规 定 的 粉 尘 分 散 度 的 测 定 方 法 包 括 滤 膜 溶 解 法 和 沉 降 法 。 ( √ ) 22、焦磷酸重量法测定粉尘中游离二氧化硅含量时,焦磷酸溶解硅酸盐时的温度不得超 过 200℃。 ( × ) 23、建设项目职业病危害预评价的评价方法包括:风险评估法、类比法、检查表分析法 三种。 ( × ) 24、《告知卡》是针对某一职业病危害因素,告知劳动者危害后果及其防护措施的提示
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:119 KB 时间:2026-04-23 价格:¥2.00
电工安全技术培训考试卷 单位; 姓名; 考试时间; 成绩; 总包安全负责人(签字); 监理安全负责人; 一、填空:(本题共 10 个小题、每小题 2 分、共 20 分) 1、对于特种作业人员,必须进行专业 和 ,经考试合格后, 才能准许其上岗操作。 2、在电气设备上使用了 电器或材料,可能造成严重后果。 3、现场使用移动式碘钨灯照明,必须采用 灯具。 4、木工房、库房等易燃易爆场所不得使用 等高热型灯具。 5、室内灯具安装高度不得小于 米。 6、现场使用镝灯时安装高度不得低于 米。 7、直埋电力电缆埋深一般应不小于 米,应在电缆上下各铺 50㎜的细沙或软 土,上用水泥板覆盖。 8、电缆干线应采用埋设或架空敷设,严禁 。 9、安全灯电压的选用,一般场所使用时不应超过 伏;在特别潮湿场所和金属容器 内使用时,不应超过 伏。 10、电气设备带电检修时,执行监护制度是保证 的主要措施。 二、判断题:(本题共 20 个小题、每个小题 2 分、共 40 分,正确的在括号内打“√”错 误的在括号内打“ⅹ”) 1、室外不得使用落地式配电柜 ( ) 2、蛙式打夯机严禁使用倒顺开关,必须使用定向开关。 ( ) 3、局部照明变压器应是双绕组的,并且一、二次侧均装设熔断器保护。 ( ) 4、同一变压器三相四线中性点直接接地系统中的电气设备,允许一部分做接地保护,一部 分做接地保护。 ( ) 5、在触电人脱离电源后,呼吸停止、心脏不跳动,如果没有致命的外伤,应迅速投入抢救。 ( ) 6、带电作业时,直接接触单相回路的零线没有危险。 ( ) 7、安装了漏电保护装置的设备,可以不做接地或接零保护。 ( ) 8、配电室内配线应使用裸导线,配线应排列整齐,连接良好。 ( ) 9、地下工程(地铁、暗挖顶管等)电源引入地下时,应在出入口地上设置配电箱控制。 ( ) 10、配电箱的编号原则:ZXA—1、2、3……,分配电箱为 FXB—1、2、3……, 开关箱为 KXC—1、 2、 3… … , 移 动 箱 为 YXD—1、 2、 3… … 。 ( ) 11、金属箱体,箱门和箱内开关电器的金属外壳及金属围栏,均需作保护零线(地)保护零 线必须采用多股绝缘铜线,统一标志为绿/黄双色线。 ( ) 12、现场配电系统实行逐级漏电保护形成分级保护。 ( ) 13、现场配电系统实行三级配电,即总配电箱—分配电箱—开关箱。 ( ) 14、配电柜应装设短路过负荷保护装置和漏电保护器就可以。 ( ) 15、现场配电室内和室外均可设落地式配电柜。 ( ) 16、交流电焊机必须安置专用的电焊机防触电保护装置。 ( ) 17、使用电气设备时应掌握安全用电基本知识和所用设备的性能。 ( ) 18、使用设备前,必须按规定穿戴和配备好相应的劳动防护用品。 ( ) 19、停用的设备拉闸断电,锁好箱门。 ( ) 20、电焊机的地线不得借用脚手架、塔吊导轨工程钢筋等设备设施。 ( ) 三、选择题:(本题共 20 个小题、每个小题 2 分、共 40 分) 1、人体对工频电流的感知电流为; ( ) A、1mA B、10mA C、30mA D、50mA 2、人体对公频电流的摆脱电流为 ( ) A、1mA B、10mA C、30mA D、50mA 3、停电检修作业时,确定没电的依据是 ( ) A、电源开关已拉开 B、电源指示灯熄灭 C、电流表的指示为零 D、经合格的验电器试验无电 4、被检修的线路停电后,在配电室控制该回路的开关操作手柄上应悬挂标示牌 A、止步!高压危险 B、以接地 ( ) C、禁止合闸,有人工作 D、禁止合闸,线路有人工作 5、一般场所下使用的漏电保护器,作为人身直接触电保护时,应选用额定漏电动作电流和 漏电动作时间 ( ) A、50mA、0.2S B、50mA、0.1S C、30mA、0.2S D、30mA、0.1S 6、开关箱与其控制的用电设备的水平距离不应超过 ( ) A、2 米 B、3 米 C、4 米 D、5 米 7、固定式配电箱(总分配电箱和开关箱)箱体中心与地面的垂直距离应 ( ) A、大于 0.8 米 B、小于 1.4 米 C、大于 1.6 米 D、大于 1.4 米、小于 1.6 米 8、配电箱的箱体宜使用铁质材料,其钢板厚度 ( ) A、不小于 0.5 毫米 B、不小于 0.75 毫米 C、不小于 1 毫米 D、不小于 1.5 毫米 9、配电箱的操作通道宽度,不应小于 ( ) A、0.6 米 B、1 米 C、1.2 米 D、1.5 米 10、配电室的天棚距地面不低于 ( ) A、1.8 米 B、2.2 米 C、2.5 米 D、3 米 11、现场配电系统,第三级漏电保护器的额定漏电动作电流应小于等于 ( ) A、15mA B、30mA C、75mA D、100mA 12、室外固定式配电箱围栏不低于 ( ) A、1.7 米 B、1.8 米 C、1.9 米 D、2 米 13、在施工现场专用变压器中性点直接接地的线路中,必须采用 接零保护系统 ( ) A、TN---C B、TN—S C、TN-C-S D、TT 14、电气设备的金属外壳必须与 连接, ( ) A、工作零线 B、相线 C、重复接地 D、专用保护零线 15、塔吊及大型机械设备的防雷接地电阻值不得大于 ( ) A、30 欧姆 B、20 欧姆 C、10 欧姆 D、4 欧姆 16、电缆在室外直接埋地敷设的深度应不小于 ( ) A、1.5 米 B、1.2 米 C、0.7 米 D、0.3 米 17、电缆穿越建筑物、构筑物、道路等场所时引出地面从 高度必须设防护套管 ( ) A、2 米 B、3 米 C、1 米 D、4 米 18、总配电箱内漏电保护器额定漏电动作电流为 ( ) A、100mA B、50mA C、75mA D、30mA 19、分配电箱内漏电保护器额定漏电动作电流为 ( ) A、100mA B、50mA C、75mA D、30mA 20、开关控制箱和移动箱漏电保护器额定漏电动作电流为 ( ) A、100mA B、50mA C、75mA D、30mA 以下
分类:安全培训材料 行业:其它行业 文件类型:Word 文件大小:20.4 KB 时间:2026-04-23 价格:¥2.00
职业病危害(职业卫生)检测评价人员复习题 一、填空(每空 0.5 分,共 25 分): 1、生产经营单位应当加强作业场所的职业危害防治工作,为从业人员提供符合法 律、法规、规章和国家标准、行业标准的 工作环境 ,采取有效措施,保障 从业 人员 的职业健康。 2、 生产经营单位 是职业危害防治的责任主体。 3、职业危害,是指从业人员在从事职业活动中,由于接触 粉尘 、放射 性 、 有毒化学物质 、物理 等有害因素而对 身体健康 所造成的各种损 害。 4、生产经营单位应当为 存在劳动关系的劳动者 建立职业健康监护档案,并按 照规定的期限妥善保存。 5、厂区总平面布置:生产区宜选在大气污染物 扩散条件好 的地段。 6、高温、热加工、有特殊要求和人员较多的建筑物应避免 西晒 。 7、当机械通风系统采用部分循环空气时,送入工作场所空气中有害气体、蒸汽及 粉尘的含量,不不应超过规定接触限值的 3% 。 8、夏季自然通风的进气窗其下端距地面不应高于 1.2m ,以便空气直接吹向 工作地点。冬季自然通风用的进气窗其下端一般不低于 4m 。如低于 4m 时,应 采取防止冷风吹向工作地点的有效措施。 9 、 当 工 作 地 点 气 温 ≥ 3 5 ℃ 时 , 应 采 取 局 部 降 温 和 综合 防暑 措施,并应减少接触时间。 10、浴室、盥洗室厕所的设计,一般按劳动者 最多的班组人数 人数设计,存衣室 设计计算人数应按 车间劳动者实际人数 计算。 11、生产或使用剧毒或高毒物质的高风险工业企业应设置 紧急救援站 或 有毒气体防护站 。 12、在《工作场所化学物质容许浓度》备注栏中,标有“皮”及“G1”字样,“皮” 指 因皮肤、黏膜和眼睛直接接触蒸气、液体和固体,通过完整的皮肤吸收引起全身效 应“G1”指 确认人类致癌物 。 13、高温危害评价中接触时间率是指:劳动者在一个工作日内实际接触高温作业的 累计时间 和 8h 的比率。 14、手传振动的测量,按照 生物力学 坐标系,分别测量三个轴向振动的 频率 计权加速度值 ,取 三个轴向的最大值 作为被测工具或工件的手传振动值。 15、煤矿井下的主要支护方式有 锚杆(锚锁)同喷支护、 支架支护 、砌碹支护、工 字钢支护和坑木支护。 16、定点采样采样点的选择应选择 有代表性的 工作地点,其中应包括有 害物质 浓度最高 、劳动者 接触时间最长 的工作地点。 17、噪声的测量:工作场所声场分布不均匀时,应将其划分若干声级区,同一声级 区内 声级差<3dB(A) 。每个区域内,选择 2-3 个测点,取平均值。 1 8 、 一 个 有 代 表 性 的 工 作 场 所 内 有 多 台 同 类 生 产 设 备 时 , 1-3 台设置 1 个采样点, 4-10 台设置 2 个采样点; 10 以上,至少设置 3 个采样点。 19、高温的测量:常年从事高温作业,在夏季最热季节 测量,不定期 从事高温作业,在 工期内最热月 测量;从事室外作业,在最热月晴天有太阳辐射时 测量。 二、判断题(每题 0.5 分,共 15 分) 1、作业场所使用有毒物品的生产经营单位,应当按照有关规定向安全生产监督管理部 门申请办理职业卫生安全许可证。 ( √ ) 2、从事易燃易爆作业的人员应穿含金属纤维的棉布工作服,以防静电危害。(√ ) 3、减少环境中尘毒的根本办法是戴防毒面具。(×) 4、对接触职业危害的从业人员,生产经营单位应当按照国家有关规定组织上岗前、在 岗期间和离岗时的职业健康检查,并将检查结果如实告知从业人员。职业健康检查费用 由生产经营单位及从业人员共同承担。 ( × ) 5、生产经营单位应当依法为从业人员办理工伤保险,缴纳保险费。 ( √ ) 6、工业企业选址应避开自然疫源地,对因建设工程需要不能避开的,不需采取相应的 措施。 ( × ) 7、在同一工业区内布置不同卫生特征的工业企业时,宜避免不同有害因素产生交叉污 染就可以。 ( × ) 8、 《 职 业 病 目 录 》 中 , 尘 肺 指 包 含 矽 肺 及 金 属 尘 肺 在 内 的 13 种 尘 肺 。 ( √ ) 9、 生 产 经 营 单 位 不 得 安 排 有 职 业 禁 忌 的 劳 动 者 从 事 有 毒 物 品 作 业 。 ( √ ) 10、GBZ2.2-2007 中所规定的采掘工作场所气象条件的标准适用于包括煤矿在内的所有 井下采掘作业。 ( × ) 11、有可能泄漏液态剧毒物质的高风险作业场所,应专设泄险渠等应急设施。 ( √ ) 12、煤矿采煤司机及助手作业时粉尘采样点应布置在距工人操作处 1.5m 下风侧。 ( √ ) 13、 特 殊 高 温 作 业 , 热 辐 射 强 度 应 小 于 700W/m2, 室 内 气 温 不 应 超 过 26℃ 。 ( × ) 14、 噪 声 与 振 动 较 大 的 生 产 设 备 应 安 装 在 单 层 厂 房 或 多 层 厂 房 的 底 层 。 ( √ ) 15、遇湿易燃物品可以露天储存。(×) 16、建设项目职业病危害控制效果评价在评价阶段应完成的工作是:工程分析、职业卫 生调查、职业病危害因素定性定量分析与评价。 ( √ ) 17、指令性标识的背景色为蓝色,标示图及外圈均为白色,安全色至少要覆盖总面积的 50%。 18、 噪 声 检 测 声 级 计 的 要 求 为 : 2 型 及 以 上 , 具 有 A 计 权 及 S 档 。 ( √ ) 19、 紫 外 线 的 测 量 应 测 量 操 作 人 员 面 、 眼 、 肢 体 及 其 它 暴 露 部 位 。 ( √ ) 20、煤矿井下凿岩工采样位置设在距工作面 3-7m 的回风侧。( × ) 21、 国 家 标 准 中 规 定 的 粉 尘 分 散 度 的 测 定 方 法 包 括 滤 膜 溶 解 法 和 沉 降 法 。 ( √ ) 22、焦磷酸重量法测定粉尘中游离二氧化硅含量时,焦磷酸溶解硅酸盐时的温度不得超 过 200℃。 ( × ) 23、建设项目职业病危害预评价的评价方法包括:风险评估法、类比法、检查表分析法 三种。 ( × ) 24、《告知卡》是针对某一职业病危害因素,告知劳动者危害后果及其防护措施的提示
分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:119 KB 时间:2026-04-24 价格:¥2.00
门窗工程技术交底 工程名称 施工员 作业班组 施工部位 质监员 班组负责人 一、交底内容: 1、 铝合金窗的窗框产能平内、外墙面安装,应按《装饰工程施工及验收规范》距墙面 60~80 安装,门窗的固定件不得采用一般铁皮,间距不得大于 600。距转达角处不得大于 150~200,采用镀锌铁皮时,其厚度不小于 1mm,宽度不小于 25mm,固定铁皮不能用水 泥钢钉钉入砖墙内,应肜塑料胀套管进行固定。与主体的连接要弹性连接。与主体结构 间隙保持 10~15mm,缝隙应先填塞发泡塑料棒、玻璃棉毡或石棉绳,再打硅酮耐候密封 胶。 2、 铝合金门窗应先做样板安装好后,经验收合格才能全面施工。 3、 木门窗的制作与安装应符合规定要求,铰链安装位置为门窗扇两端距门窗边长的 1/10 处, 大小符合要求,主合页应固定在框上(座三挑二),应双面刻槽且深度一致,上下冒头应 刷油漆,油漆不能污染小五金,木夹板门的内框肋上应留 3 个通气孔。三角铁和风钩安 装位置要正确,窗扇开启后挂上风钩应与墙面垂直。 4、 木门窗框与墙、梁、柱接触面要刷防腐涂料。木窗框底框安装要比窗台砌体高 40~60mm, 以便做排水坡度。 5、 防火门开启方向应与人流疏散方向相同。 6、 玻璃安装:a.木门窗的玻璃条每边每根玻璃条不允许有接头,四角应是 45 度拼角,压条 的无钉间距不大于 300mm,元钉不能露头,玻璃条安装后不能突出门窗平面。b 铝合金 门窗的玻璃条安装禁止使用再生密封胶条,每边胶条下料长度(无拉伸),应比门窗扇内 空边长长 10~15mm,胶条接头应设在门窗扇转角处,胶条必须把玻璃卡紧外观顺直无松 动和脱落现象。 二、允许偏差项目 1、 框的正、侧面垂直:3 mm 2、 框对角线长度差:2 mm 3、 框与窗扇及扇与扇接触高低差:2 mm 4、 门窗扇对口缝、扇与框缝:1。5~2。5 mm 5、 工业厂房双扇大门对口缝:2~5 mm 6、 框与扇上缝:1~1。5 mm 7、 窗与下坎间缝:2~3 mm 8、 门扇与地面间隙:a .外门:4~5,b 内门 6~8,c 卫生间门:10~12,d.厂房大门:10~20 接受交底人员签名: 2000 年 月 日
分类:安全管理制度 行业:建筑加工行业 文件类型:Word 文件大小:34.5 KB 时间:2026-04-29 价格:¥2.00