大约有19000项符合查询结果,库内数据总量为28017项,搜索耗时:0.0165秒。

005 施工项目应急处置流程告知卡汇编

目录 1. 火灾事故现场应急处置方案......................................................................................................2 2. 触电事故现场应急处置方案......................................................................................................4 3. 高处坠落事故现场应急处置方案..............................................................................................6 4. 群体食物中毒现场应急处置方案..............................................................................................8 5. 交通事故现场应急处置方案....................................................................................................10 6. 机械伤害事故现场应急处置方案............................................................................................12 7. 中暑现场应急处置方案............................................................................................................14 8. 物体打击事故现场应急处置方案............................................................................................16 9. 突发疾病现场应急处置方案....................................................................................................18 10. 灼伤事故现场应急处置方案..................................................................................................20 11. 塌方(坍塌)事故现场应急处置方案..................................................................................22 12. 脚手架事故现场应急处置方案..............................................................................................24 13 地质灾害现场应急处置方案....................................................................................................26 14. 恶劣天气现场应急处置方案..................................................................................................28 15. 洪水灾害现场应急处置方案..................................................................................................30 16. 环境污染事件应急处置方案..................................................................................................32 17. 输电线路上作业人员遭遇雷电事故现场应急处置方案......................................................34 18. 溺水事件应急处置方案..........................................................................................................36 19. 人身伤亡事故现场应急处置方案..........................................................................................38 20. 急性传染病现场应急处置方案..............................................................................................41 1. 火灾事故现场应急处置方案 火灾事故现场应急处置方案 事故 特征 事故类型:气体火灾、液体灾害、固体可燃物火灾。 危害程度:火灾生成的有毒、有害或窒息性气体易使人员中毒或缺氧窒息死亡,燃 烧的火焰会造成人员烧伤或死亡。 事故征兆:焦糊味、烟、火光、电气产品突然损坏或温度异常升高、线路产生火花。 发生条件:有可燃物,有氧气或氧化剂,有热源。 应急 组织 及职 责 组长:,联系方式:xx 职责:负责指挥灭火和人员财产的抢救工作,向各职能组下达抢救指令任务,根据 火灾情况判断是否向 119、120 等有关部门报告和求援。 副组长:xx,联系方式:xx 职责:协调各组之间的抢救工作,协助组长指挥现场应急救援工作,组长不在现场时, 承担指挥职责。 成员:安全部:xx,联系方式: xx 职责:负责现场处置 物资供应:xx ,联系方式: xx 职责:负责抢险、救援物资、器材器具的供应。 综合办公室:xx,联系方式: xx 职责:负责报告公司总部及相关单位,根据组长指令向 119、120 求援,负责安排车 辆。 现场安全保卫:各工区主任及现场技术员 职责:负责组织消防人员进行火灾扑救,物资抢救,对事故现场划定警戒区,阻止 与救援无关人员进入现场。 应急 处置 程序 1. 现场人员第一时间报警,及时通知现场负责人。 2. 现场负责人、现场处置小组成员接到报告应立即联系各应急处置部门及时赶到 火灾地点。 3. 组长到达现场后应根据火情,按照应急处置措施组织义务消防队和现场施工人 员进行自救。 4. 火灾事故超出应急能力时,向当地政府及上级主管部门请求支援。 应急 处置 措施 1.最先发现火情的人要大声呼叫,某某地点或某某部位失火,并报告单位负责人。向 内部报警时,报警人员应叙述:出事地点、情况、报警人姓名;向外部报警时,报警 人应详细准确报告:出事地点、单位、电话、事态现状及报告人姓名、单位、地址、 电话;报警完毕报警员应到路口迎接消防车及急救人员的到来。 2.现场负责人负责现场总指挥。打电话通知 119 报告失火地点,火势以及联系人和联 系电话,同时通知主管领导。 3.按应急方案立即进行自救。火灾初起阶段可用灭火器灭火,用消防桶提水,用铁锹 铲土等力争在火灾初起阶段,将火扑灭。若事态严重,难以控制和处理,应在自救 的同时向专业救援队求助。 4.由电工负责切断电源,防止事态扩大。 5.在组织扑救的同时,组织人员清理、疏散现场人员和易燃易爆、可燃材料。如有物

分类:事故与应急 行业:建筑加工行业 文件类型:Word 文件大小:207 KB 时间:2025-08-16 价格:¥2.00

37 高空施工安全协议书

高空施工安全协议书 甲方: 乙方: 甲方、乙方为保证文明施工,消防治安安全管理及高空作业安全管理,根据 有关规定签订安全协议,双方应共同遵守。 一、 甲方责任: 1、根据消防治安安全管理规定及高空作业安全管理规定有权对乙方的施工 进行监督,要求乙方按施工方案进行施工。若乙方未按施工方案进行施工,或违 反相关安全规定、违章施工,有权停止乙方施工。 2、不承担施工中的任何费用和一切相关责任。 二、乙方责任 1、应将施工方案叫甲方备案,并向甲方提供施工人员名单及各相关工种的 从业资格证件等。 2、应明确施工现场安全负责人一名,负责对施工人员安全教育及施工培训, 确保施工现场安全,做好文明施工、消防治安安全管理及高空作业安全管理的监 督检查和协调工作。 3、确保所有材料均符合国家相关检测标准。 4、不得雇佣精神精神病患者、呆傻人员、劳改、劳教、少管人员及缓刑、 假释、监外执行、取保候审、保外就医、刑事拘留等人员进行施工。 5、确保在施工中杜绝赤膊光脚等不文明现象,施工人员要做好个人卫生。 6、施工过程中的施工人员安全责任均由乙方负责。 7、在施工范围内如对第三方(人、物)造成伤害,其后果由乙方负责,并 承担全部责任;如对甲方原有设备及成品等物品造成损坏的,由乙方负责对损毁 物品进行赔偿。 8、乙方在施工时不得随意动用明火作业或私自存放易燃、易爆物品,如因 施工需要,需动用明火作业,乙方应事先挣得甲方同意,并提出书面申请批准后, 方可使用。并由乙方派专人负责现场施工安全,保证安全无事故。如乙方私用明 火、私存放易燃易爆等物品,产生的一切后果均由乙方负责。 9、乙方在施工中,不得随意扩大施工占地面积,严禁堵塞交通及楼宇安全 疏散通道,各种施工材料,设备不得乱堆乱发。对施工中遗留的各种废料及物品, 应做到当天施工当天清理,保证施工现场的清洁卫生。 10、乙方在施工中要确保用电安全,严防发生触电事故,杜绝一切不安全隐 患,定期对现场进行安全检查,不得随意拉、接临时电源线、裸线或直接插在电 源插座上,如因乙方用电不慎所造成的一切后果由乙方负责。 11、乙方在施工过程中不得随意拆改移动消防专用设施设备。 12、乙方如因管理不善等原因,导致施工现场混乱、发生事故等产生的后果 均由乙方承担全部责任并负责赔偿。事情严重的,甲方和乙方有权令其停工整顿, 并协助司法部门追究有关人员的刑事责任。 13、乙方在施工中人员凡在离地面两米以上进行的作业,都属于高空作业。 所有高空作业者,不论什么工种,进行作业的时间、地点,也不论专业或临时, 均应执行高空作业安全管理规定。 14、从事高空作业的施工人员,必须进行身体检查。凡患有高血压、心脏病、 癫痫病、恐高症及其他不适应高空作业的人员,一律不准从事高空作业的施工。 15、凡遇有下列情况之一时,应停止露天高空作业: (1)闪电、打雷、暴雨; (2)六级以上大风; (3)钢管上雨水未干; (4)可能发生危险的其他情况。 当上述情况过后,必须经安全员和有关技术人员检查各种作业设备,确认无 问题后,才能恢复施工。 16、高空作业现场,应划出危险禁区,设置明显标志,严禁无关人员进入。 17、凡经常高空作业的施工人员,应配备工具袋,高空作业使用的小型工具, 均应装入工具袋内,不准在钢管上或脚手架乱放工具。 18、登高作业前,应仔细检查登高工具和安全用具,如安全帽、安全带、梯 子、跳板、脚手架等,如有不符合要求的应立即改进或停止登高作业。 19、所有高空作业人员,不准穿硬底鞋,一律使用安全带。安全带应高挂低 用,即将安全带绳端挂钩挂在高处,施工人员在较低处进行作业。

分类:安全培训材料 行业:其它行业 文件类型:Word 文件大小:24.8 KB 时间:2025-08-21 价格:¥2.00

49 施工现场安全用电协议

施工现场安全用电协议 一、安全技术操作要求 1 .线路敷设 1.1 电缆干线应采用穿管埋地敷设,严禁沿地面明设和随地拖拉。 以免机械损伤和介质腐蚀。直埋时其表面距地面的距离不宜小于 0.7m ; 在电缆上下辅以 50 ㎜厚软土或砂土,盖砖保护,并有明确标示。 1.2 埋地敷设电缆的接头应设在地面上的接线盒内,接线盒应能防 水。电缆接头应牢固可靠;并应做绝缘防水包扎,保持绝缘强度,不 得承受张力。 1.3 施工现场临时加工场的照明必须要设独立的控制开关和漏电断 路器,其漏电动作电流≤ 30mA 、 0.1s 高度应大于 2.4m 。 1.4 现场办公室、施工现场、施工通道、夜间警示照明灯具与地面 高度不底于 2.4m 、室外照明灯不低于 3m 。 2 、对配电箱和开关箱的要求 ,配电箱和开关箱选择及安装基本 原则是保证设备在正常和故障情况下,可靠分断电源,在漏电情况下 能迅速使设备和人员脱离电源。故应遵守以下几项原则: 2.1 箱内所采用的开关电器必须是合格产品,必须完整无损、动作 可靠,绝缘良好。 2.2 分配电箱内应设刀闸隔离开关,箱内的漏电断路器与配电线路 一一对应,其漏电动作值约大于开关箱,以确保在下级电箱故障不能 分断的情况下起到补充保护作用。 2. 3 手动开关电器只许用于小容量的用电设备 (5 . 5KW 以下 ) 和 照明电路。容量大于 5 . 5KW 的动力设备,尤其是电动机电路,因手 动开关通断电速度慢,容易产 生强电弧,灼伤人或电器,故采用自动 开关或接触器等进行控制。 2. 4 配电箱在材质上的要求:施工现场严禁木质材料制作配电箱, 故宜采用带锁金属制品或玻璃钢制品制作的标准配电箱。 2. 5 配电箱内部开关、电器安装要求: 配电箱、开关箱及其内部开关箱电器的所有正常不带电的金属部 件均应作可靠的保护接零,保护零线必须采用标准的绿/黄双色多股 铜芯线,通过专用接线端子板可靠连接,与工作零线区别标识。大容 量设备电缆和进出电箱主电缆,必须焊接或压接线鼻子再与开关或端 子板连接。 箱内电器安装常规是左大右小,大容量的控制开关,熔断器在左 面,右面安装小容量的开关电器。 2. 6 电缆(线)进出配电箱、开关箱,应下进下出;进、出口处加 强绝缘,并将导线卡牢固。使其美观安全,禁止从箱体的左、右、上 方进出线。 2.7 配电箱、开关箱必须防雨,防尘,箱体应严密、端正,箱门开 关松紧适当,便于开关;必须有门锁;端子板一般做在箱体配电板下 部或箱内底侧边,并应分别标明“ N ”“ PE ”。 2.8 配电箱、开关箱应在箱门上清晰地标注其编号、名称、用途、 责任人,并作分路标志,箱门内应贴上相应的控制线路图。所有配电 箱、开关箱均应配锁,专箱专用。箱面上清晰地标注《有电危险》警 示符号标志。 2.9 配电箱、开关箱的操作要求: ①操作者必须持证上岗,并掌握基本的安全用电知识和使用性能, 熟悉有关开关电器的正确操作方法。操作者上岗时应按规定穿戴合格 的绝缘劳保用品,并检查确定开关箱及控制设备、线路和保护设施完 好后,方可操作。 ②通电后发现有翁翁声而电机不转动,则应立即拉闸断电,请专 业电工进行检查,待消除故障后,才可重新操作。 2.10 配电箱、开关箱的维修技术措施: ①配电箱、开关箱应每月检查一次,并做好定期与巡检的检查维 修记录;在维修时必须将前一级的相应电源开关拉闸断电,并悬挂停 电检修标志牌。同时还必须验电,确定无电后方可维修。

分类:安全培训材料 行业:其它行业 文件类型:Word 文件大小:34.3 KB 时间:2025-08-22 价格:¥2.00

施工现场安全用电协议(13页)

施工现场安全用电协议 一、安全技术操作要求 1 .线路敷设 1.1 电缆干线应采用穿管埋地敷设,严禁沿地面明设和随地拖拉。 以免机械损伤和介质腐蚀。直埋时其表面距地面的距离不宜小于 0.7m ;在电缆上下辅以 50 ㎜厚软土或砂土,盖砖保护,并有明确标示。 1.2 埋地敷设电缆的接头应设在地面上的接线盒内,接线盒应能防 水。电缆接头应牢固可靠;并应做绝缘防水包扎,保持绝缘强度,不 得承受张力。 1.3 施工现场临时加工场的照明必须要设独立的控制开关和漏电断 路器,其漏电动作电流≤ 30mA 、 0.1s 高度应大于 2.4m 。 1.4 现场办公室、施工现场、施工通道、夜间警示照明灯具与地面 高度不底于 2.4m 、室外照明灯不低于 3m 。 2 、对配电箱和开关箱的要求 ,配电箱和开关箱选择及安装基本 原则是保证设备在正常和故障情况下,可靠分断电源,在漏电情况下 能迅速使设备和人员脱离电源。故应遵守以下几项原则: 2.1 箱内所采用的开关电器必须是合格产品,必须完整无损、动作 可靠,绝缘良好。 2.2 分配电箱内应设刀闸隔离开关,箱内的漏电断路器与配电线路 一一对应,其漏电动作值约大于开关箱,以确保在下级电箱故障不能 分断的情况下起到补充保护作用。 2. 3 手动开关电器只许用于小容量的用电设备 (5 . 5KW 以下 ) 和 照明电路。容量大于 5 . 5KW 的动力设备,尤其是电动机电路,因手 动开关通断电速度慢,容易产 生强电弧,灼伤人或电器,故采用自动 开关或接触器等进行控制。 2. 4 配电箱在材质上的要求:施工现场严禁木质材料制作配电箱, 故宜采用带锁金属制品或玻璃钢制品制作的标准配电箱。 2. 5 配电箱内部开关、电器安装要求: 配电箱、开关箱及其内部开关箱电器的所有正常不带电的金属部 件均应作可靠的保护接零,保护零线必须采用标准的绿/黄双色多股 铜芯线,通过专用接线端子板可靠连接,与工作零线区别标识。大容 量设备电缆和进出电箱主电缆,必须焊接或压接线鼻子再与开关或端 子板连接。 箱内电器安装常规是左大右小,大容量的控制开关,熔断器在左 面,右面安装小容量的开关电器。 2. 6 电缆(线)进出配电箱、开关箱,应下进下出;进、出口处加 强绝缘,并将导线卡牢固。使其美观安全,禁止从箱体的左、右、上 方进出线。 2.7 配电箱、开关箱必须防雨,防尘,箱体应严密、端正,箱门开 关松紧适当,便于开关;必须有门锁;端子板一般做在箱体配电板下 部或箱内底侧边,并应分别标明“ N ”“ PE ”。 2.8 配电箱、开关箱应在箱门上清晰地标注其编号、名称、用途、 责任人,并作分路标志,箱门内应贴上相应的控制线路图。所有配电 箱、开关箱均应配锁,专箱专用。箱面上清晰地标注《有电危险》警 示符号标志。 2.9 配电箱、开关箱的操作要求: ①操作者必须持证上岗,并掌握基本的安全用电知识和使用性能 ,熟悉有关开关电器的正确操作方法。操作者上岗时应按规定穿戴合 格的绝缘劳保用品,并检查确定开关箱及控制设备、线路和保护设施 完好后,方可操作。 ②通电后发现有翁翁声而电机不转动,则应立即拉闸断电,请专 业电工进行检查,待消除故障后,才可重新操作。 2.10 配电箱、开关箱的维修技术措施: ①配电箱、开关箱应每月检查一次,并做好定期与巡检的检查维 修记录;在维修时必须将前一级的相应电源开关拉闸断电,并悬挂停 电检修标志牌。同时还必须验电,确定无电后方可维修。

分类:安全培训材料 行业:其它行业 文件类型:Word 文件大小:34.3 KB 时间:2025-08-22 价格:¥2.00

高空施工安全协议书(3页)

高空施工安全协议书 甲方: 乙方: 甲方、乙方为保证文明施工,消防治安安全管理及高空作业安全管理,根据 有关规定签订安全协议,双方应共同遵守。 一、 甲方责任: 1、根据消防治安安全管理规定及高空作业安全管理规定有权对乙方的施工 进行监督,要求乙方按施工方案进行施工。若乙方未按施工方案进行施工,或违 反相关安全规定、违章施工,有权停止乙方施工。 2、不承担施工中的任何费用和一切相关责任。 二、乙方责任 1、应将施工方案叫甲方备案,并向甲方提供施工人员名单及各相关工种的 从业资格证件等。 2、应明确施工现场安全负责人一名,负责对施工人员安全教育及施工培训, 确保施工现场安全,做好文明施工、消防治安安全管理及高空作业安全管理的监 督检查和协调工作。 3、确保所有材料均符合国家相关检测标准。 4、不得雇佣精神精神病患者、呆傻人员、劳改、劳教、少管人员及缓刑、 假释、监外执行、取保候审、保外就医、刑事拘留等人员进行施工。 5、确保在施工中杜绝赤膊光脚等不文明现象,施工人员要做好个人卫生。 6、施工过程中的施工人员安全责任均由乙方负责。 7、在施工范围内如对第三方(人、物)造成伤害,其后果由乙方负责,并 承担全部责任;如对甲方原有设备及成品等物品造成损坏的,由乙方负责对损毁 物品进行赔偿。 8、乙方在施工时不得随意动用明火作业或私自存放易燃、易爆物品,如因 施工需要,需动用明火作业,乙方应事先挣得甲方同意,并提出书面申请批准后, 方可使用。并由乙方派专人负责现场施工安全,保证安全无事故。如乙方私用明 火、私存放易燃易爆等物品,产生的一切后果均由乙方负责。 9、乙方在施工中,不得随意扩大施工占地面积,严禁堵塞交通及楼宇安全 疏散通道,各种施工材料,设备不得乱堆乱发。对施工中遗留的各种废料及物品, 应做到当天施工当天清理,保证施工现场的清洁卫生。 10、乙方在施工中要确保用电安全,严防发生触电事故,杜绝一切不安全隐 患,定期对现场进行安全检查,不得随意拉、接临时电源线、裸线或直接插在电 源插座上,如因乙方用电不慎所造成的一切后果由乙方负责。 11、乙方在施工过程中不得随意拆改移动消防专用设施设备。 12、乙方如因管理不善等原因,导致施工现场混乱、发生事故等产生的后果 均由乙方承担全部责任并负责赔偿。事情严重的,甲方和乙方有权令其停工整顿, 并协助司法部门追究有关人员的刑事责任。 13、乙方在施工中人员凡在离地面两米以上进行的作业,都属于高空作业。 所有高空作业者,不论什么工种,进行作业的时间、地点,也不论专业或临时, 均应执行高空作业安全管理规定。 14、从事高空作业的施工人员,必须进行身体检查。凡患有高血压、心脏病、 癫痫病、恐高症及其他不适应高空作业的人员,一律不准从事高空作业的施工。 15、凡遇有下列情况之一时,应停止露天高空作业: (1)闪电、打雷、暴雨; (2)六级以上大风; (3)钢管上雨水未干; (4)可能发生危险的其他情况。 当上述情况过后,必须经安全员和有关技术人员检查各种作业设备,确认无 问题后,才能恢复施工。 16、高空作业现场,应划出危险禁区,设置明显标志,严禁无关人员进入。 17、凡经常高空作业的施工人员,应配备工具袋,高空作业使用的小型工具, 均应装入工具袋内,不准在钢管上或脚手架乱放工具。 18、登高作业前,应仔细检查登高工具和安全用具,如安全帽、安全带、梯 子、跳板、脚手架等,如有不符合要求的应立即改进或停止登高作业。 19、所有高空作业人员,不准穿硬底鞋,一律使用安全带。安全带应高挂低 用,即将安全带绳端挂钩挂在高处,施工人员在较低处进行作业。

分类:安全培训材料 行业:其它行业 文件类型:Word 文件大小:25.6 KB 时间:2025-08-23 价格:¥2.00

4.施工单位安全生产工作计划

Print 施工单位安全生产工作计划   安全生产 工作计划   目 录   一、 安全工作目标   二、 严格执行安全生产考核制度   三、 提高管理及业务素质,加强机构人员配备   四、 加强安全宣传、教育培训,深入开展安全生产会议   五、 加大安全监督检查力度,严格奖罚   六、 强化项目管理、制定达标计划   七、 加强安全防护用品及设施的监督管理   八、 完善应急救援预案工作   九、 合理使用安全生产管理费用,切实做到专款专用   十、 做好施工现场安全管理和安全防护措施工作   为加强对***施工安全管理,有效防范各种安全事故的发生,我单位以“安全第 一,预防为主”以及“谁主管,谁负责”的安全方针为指导思想,认真贯彻落实《中 华人民共和国安全生产法》、《中华人民共和国建筑法》、《国务院关于特大安全 事故行政责任追究的规定》、《建设工程安全生产管理条例》、《安全生产许可证 条例》等各项安全生产法规、规范的实施,全面落实安全目标管理责任制考核,控 制各类事故的发生,确保业主、监理及公司各项安全工作目标任务的圆满完成。现 制定***安全生产工作计划如下:   一、安全工作目标   本标段工程安全管理目标为:杜绝重大安全事故发生,轻伤事故发生率控制 于千分之一,实现施工全过程安全生产。方针为:安全第一,预防为主;谁主管, 谁负责。   二、严格执行安全生产考核制度   根据《中华人民共和国安全生产法》的要求,我部将完善安全生产责任制的制 定,全面落实安全生产责任制,层层签定安全生产目标责任书。同时,我单位结合 实际,制定有针对性的实施细则,使安全目标责任层层细化与量化,落实到各职能 部门、项目部、班组、重要岗位及特殊岗位个人。坚持“管生产必须管安全”的原则 ,定期召开安全专题会议,组织参加安全检查,听取安全生产汇报,保证人、财、 物的投入,做到安全工作与生产任务同计划、同布置、同检查、同总结、同评比。   三、提高管理及业务素质,加强机构人员配备   1、及时完善各项安全规章制度,做到安全工作有法可依、有理有据,根据实 际情况调整安全管理重点,根据人员调动,调整安全领导小组成员,积极主动的迎 接各项上级安全检查工作,总结各项安全工作中的不足,积极改进,创新创誉。   2、加强我部安全人员的配备,加强专业学习培训,逐步提高安全人员业务能 力,以提高整体安全人员素质。   3、我部安全员的配备须经培训合格持证上岗。   4、坚决执行事故隐患整改领导负责制。实行逐级管理,施工现场中存在的事 故隐患必须由我部分管领导负责,限期整改落实。   四、加强安全宣传、教育培训,深入开展安全生产会议   1、定期召开安全生产例会,每月不少于一次安全例会、安全大检查,每季度 不少于一次安全综合评比,奖罚分明,促进安全工作。对安全意识淡薄,不重视安 全工作的管理人员、施工人员要进行相应的处罚,确保安全体系正常运行。   2、重视安全培训教育,每季度不少于一次安全培训教育活动,组织管理人员 、施工人员进行安全知识竞赛、观看安全影片、安全谜语竞猜等活动,丰富安全工 作,更好的达到安全宣传的效果。   3、加强特殊工种岗位作业人员的培训、取证、复审的检查管理,定期分批组 织特殊工种作业人员到有关单位进行上岗证培训,严禁无证上岗。   4、广泛利用施工安全简报、黑板报、宣传栏、标语等形式多样的'安全教育方 式,深入开展各种宣传教育,定期组织各工种人员进行安全知识培训,并将宣传、 培训记录用图片或书面资料的形式存档。   5、对工地新进场人员进行安全“三级”教育,教育形式应多种多样,切实可行 ,并作好教育记录,经考试合格者后方准上岗作业,教育率应达 100%。   6、组织专职安全管理人员及施工安全员学习《中华人民共和国安全生产法 》、《建设工程安全生产管理条例》,增强安全管理的法制观念,提高认识水平和 业务水平。

分类:安全培训材料 行业:其它行业 文件类型:Word 文件大小:32.5 KB 时间:2025-08-25 价格:¥2.00

工程部与技术员责任书

安全生产责任状 甲方:薛文飞 (工程部长) ,以下简称甲方 乙方:陈 雷 (技术员) ,以下简称乙方 为进一步贯彻“安全第一,预防为主,综合治理”的安全生产方针,牢牢坚 守“发展决不能以牺牲人的生命为代价”红线,建立健全“党政同责、一岗双责、 齐抓共管”的安全监管基本框架,有效遏制职业健康、安全环保、安全生产责任 事故发生,结合本项目工程实际,特签订本责任书,以明确双方的责任和义务。 一、甲方职责 1、负责项目施工方面的安全生产管理工作,保证所采用的施工方案、措施、 工艺的安全可靠,及时改进技术上存在的问题;是项目的施工安全隐患整改落实 部门。 2、编制施工中采用的新技术、新工艺、新材料、新设备相关安全技术措施, 做到技术上合理可行、安全可靠。 3、在编制实施性施工组织设计时,必须同时有安全和环保管理方案、有保 证安全生产的要求、设计和针对性的技术措施,特别是对员工驻地、办公区、拌 和场、预制场、加工厂、堆料场和支架、防护、吊装等设施的设置上。 4、进行施工设计,编制生产、安全技术交底文件,对施工过程、施工场所、 机械设备使用维护和材料装卸、储运管理过程中的危险源进行辩识;编制风险控 制计划。 5、负责项目试验检测、测量控制的管理及其质量安全工作,确保测试数据 和结果的安全可靠、及时有效。 6、负责审核图纸、严格照图施工,确保工程实体及其辅助施工设施的强度、 刚度、稳定性、耐久性及其几何尺寸、表面外观等符合设计要求,以保证其安全、 可靠、满寿命使用。 7、在指导、实施、检查现场施工时,要同时指导、实施、检查现场的安全 施工措施的有效性、可靠性,对发现的安全隐患有指令纠正的权利和向有关人员 报告的义务。 8、负责项目工程竣工资料的安全保管、搜集整理等工作。 9、参加对生产安全事故和严重环境污染事故的调查处理,并提出防止事故 重复发生的技术措施。 10、负责项目工程质量安全的检查检验,保证工程安全、正常使用,是项 目的施工质量隐患整改落实部门。 11、定期收集发布与本项目施工生产有关的安全技术规程、标准、规范。 12、制定、审查施工方案时,要同时制定、审查安全保证措施,避免因质量 问题引发的安全事故。 13、检查工程质量时,要同时检查安全网、脚手架、护栏、各种坑口防护装 置、标志信号等安全设施的质量问题。 14、参与研究、处理重大安全技术问题。 二、乙方职责 1、协助本项目领导认真贯彻“安全第一、预防为主、综合治理”的安全生 产方针,对主管工作的技术安全生产负责。 2、在使用新工艺、新技术、新材料、新设备前应检验其安全可靠性,并与 项目专职安全生产监督管理人员共同研究,加强安全防范措施、防范安全事故的 发生。 3、在进行施工设计、现场指导、检验监督施工的过程中,将生产安全放在 头等位置予以重点关注,随时纠正解决所发现的安全隐患;对自己无力解决的问 题及时向上级技术负责人报告,将事故隐患消灭在萌芽状态。 4、按分工负责编制施工技术交底和安全技术交底文件,在向相应作业班组、 施工操作人员进行第三级施工技术交底、培训的同时进行安全技术交底、培训, 并随时深入现场解决施工生产中的安全问题。 5、模范遵守各项安全管理制度和操作规程,不违章指挥生产。 6、做好主管范围内的安全宣传教育工作。 7、发生安全事故时有视具体情况立即组织抢险或组织员工撤离现场、报告 项目专职安全生产监督管理人员的职责。 三、安全生产管理目标 本项目职业健康、安全环保、安全生产管理目标为: (一)杜绝发生有人员死亡的一般以上生产安全责任事故; (二)杜绝发生有人员死亡的一般以上水上交通责任事故; (三)杜绝发生负有建设管理责任的有人员死亡的一般及以上生产安全责任 事故;

分类:安全培训材料 行业:建筑加工行业 文件类型:Word 文件大小:41.2 KB 时间:2025-09-01 价格:¥2.00

涵洞施工安全交底签证表

安全交底签证表 工程名称 杭瑞国家高速公路湖南省岳阳至常德公 路 交底编号 交底里程 K62+755 交底项目 涵洞施工安全技 术 一、一般要求 1、现场施工人员必须佩戴安全帽,电焊工工作时必须佩戴眼镜。 2、基坑开挖时放坡不小于 1:1,若交底另有要求,严格按交底执行;若因现场 条件限制放坡不足时应设置足够牢固的支挡设施。开挖出的弃土离基坑边堆放 距离至少应大于 1m,且堆放高度不超过 2m。开挖完成后,应在基坑四周设置防 护栏杆及醒目标志牌,非施工人员不得靠近。 3、配电箱以及其它供电设备不得置于水中,电线接头要牢固,并且要绝缘, 输电线路必须设有漏电开关。 4、挖掘机及吊车工作时,必须有专人指挥,并且在其工作范围内不得站人。 5、砼运输车进出场必须打开转向灯,入场后倒车必须设设专人指挥。 6、吊车、挖掘机等机械工作之前必须进行机械安全检查。 7、施工作业平台必须规整平顺,杂物必须清除干净;现场卸料前,必须检查 卸料方向是否有人,以避免将人员砸伤。 8、夜间施工,注意照明安全、交通安全、超重安全、用电安全几项措施,夜 间施工有值班领导在场。 9、严禁疲劳施工、要严格执行安全管理制度,每个工作面最少安排 2 组工作 组,每班工作组施工人员每天上岗不得超过 8 小时,以免造成意外事故。 二、焊接安全要点 1、焊接设备上的电机、电器等应有完整的防护外壳,一、二次接线柱处应有保护罩。 2、现场使用的电焊机应设有可防雨、防潮、防晒的机棚,并备有消防用品。 3、焊接时,焊接和配合人员必须采取防止触电、高空坠落、瓦斯中毒和火灾 等事故的安全措施。 4、接地线及手把线都不得搭在易燃易爆和带有热源的物品上,接地线不得接 在管道和建筑物金属构件上,接地电阻不大于 4Ω。 5、 雨天不得露天电焊,在潮湿地带作业时,操作人员应站在铺有绝缘物品的 地方并穿好绝缘鞋。 6、烛钳应与手把线连接牢固,不得用胳膊夹持焊钳。清除焊渣时,面部应避 开被清的焊缝。 7、施焊现场 10m 范围内,不得堆放氧气瓶、乙炔发生器、木材等易燃易爆 物。 8、作业后,清理场地、灭绝火种,切断电源,销好电闸箱,消除烟云料余热 后,方可离开。 三、施工用电注意事项 1、施工现场所有电气设备的胶皮线及其绝缘性能必须保持良好;凡是裸露带电部位的电 气设备和易发生电击危险的区域,设置安全警示标志,严禁乱接电线,手持式用电设备应 该配置漏电保护器。 2、临时供电线路,应用瓷夹固定,保险丝应按用电负荷配置,动力线路不得使用裸线, 电气设备的金属外壳及支架配电盘等,均应有可靠的接地装置,露天设置的所有闸刀开 关,设在闸刀箱内加锁,闸刀箱设遮雨棚。 3、凡是裸露带电部位的电气设备和易发生电击危险的区域,设置安全警示标志。夜间施 工应设置足够的照明设备,应使用防爆灯。 四、吊装作业安全注意事项 1、起重工必须经专门安全技术培训,考试合格持证上岗。严禁酒后作业。 2、起重机作业时必须确定吊装区域,并设警戒标志,必要时派人监护。作业时必须正确 选择吊点的位置,合理穿挂索具,试吊。除指挥及挂钩人员外,严禁其他人员进入吊装作 业区。 3、恶劣气候如大雨、大雾和施工作业面有六级(含六级)以上的强风影响安全施工时应暂 停吊装作业;起重机发生漏电现象应暂停吊装作业;钢丝绳严重磨损,达到报废标准时应 暂停吊装作业;安全保护装置失效或显示不准确时应暂停吊装作业。 4、作业前必须检查作业环境、吊索具、防护用品。吊装区域无闲散人员,障碍已排除。 吊索具无缺陷,捆绑正确牢固,被吊物与其他物件无连接。确认安全后方可作业。

分类:安全培训材料 行业:其它行业 文件类型:Word 文件大小:25.6 KB 时间:2025-09-04 价格:¥2.00

风险隐患表格清单-附件:建筑施工安全生产大督查大执法重点行为检查清单

督查组: 形象进度 业主代表姓名 与联系电话 项目经理姓名 与联系电话 项目总监姓名 与联系电话 设计单位 检测单位 项目经理本次 记分 序号 本次检 查项 行为主 体 检查项目 主要内容 督查意见 □未办理安全监督手续 □办理安全监督手续滞后 □未办理施工许可 □施工许可办理滞后 □建设范围超出施工许可允许范围 □未在施工合同中单列安全文明施 工费; □未在开工前将安全文明施工费拨 付给施工单位 □未检查安全文明施工费使用情况 并督促落实安全文明施工措施。 □未参与对危大工程安全管理 □接到安全隐患报告后,未督促施 工单位立即整改 □应实行第三方监测的未按规定进 行监测 □应组织相关评估、论证而未组织 的 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □不符合 □不符合 □不符合 □不符合 安全报监资料 施工许可证 支付凭证、检查记 录 相关审查、检查资 料与工作记录 办理安全监督手 续情况 施工许可办理 安全文明施工费 危大工程安全管 理 建 设 单 位 □ □ □ □ 一、建设单位安全生产重点行为 检查情况 □符合 □符合 □符合 □符合 1 2 3 4 分包单位 监测单位 监理单位 重庆市建新建设监理咨询有限公司 乔守江 勘察单位 建设单位 重庆市宏安房地产开发有限公司 杨义彬 施工单位 重庆市荣昌区华兴建筑工程有限公司 刘杰 附件 建筑施工安全生产大督查大执法重点行为检查清单 督查时间: 年 月 日 督查地区: 工程名称 广顺虹杉园 1#楼主体、2#楼主体 第 1 页,共 6 页 □未收集并提供施工现场、毗邻区 域地下管线和建(构)筑物准确、 完整的现状资料 □应督促制定安全保护措施方案而 未督促的 □不符合 □未按照《关于进一步加强城市轨 道交通工程关键节点风险管控工作 的通知》(渝建〔2017〕639号), 开展正式核查工作。 序号 本次检 查项 行为主 体 检查项目 主要内容 督查意见 □超出资质许可范围承担业务 □资质证书不在有效期内 □施工企业未取得或因故被吊销安 全生产许可证 □安全生产许可证不在有效期内 □不符合 □存在违法分包行为 □不符合 □存在转包行为 □人员变更未办理相关手续 □变更人员资格不满足相关规定 □施工单位变更后未重新办理或变 更施工许可证 □变更后的施工单位资质、人员资 格或数量不满足相关规定 □符合 □未建立安全文明施工费使用管理 制度 □未建立安全文明施工费使用计划 □未单独建立安全文明施工费使用 台账 □未专款专用,将安全文明施工费 挪作他用。 □未建立、落实项目安全生产责任 制 □未确保项目安全生产费用有效使 用 □未有效监控项目危大工程管理 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □不符合 □不符合 □不符合 □不符合 □不符合 □不符合 □不符合 施工许可证、单位 资质证书、人员资 格证书 相关制度、计划、 台账等资料 安全生产责任制、 安全生产带班记录 、安全考核记录等 安全台账与现场 核查资料 施工单位资质证书 安全生产许可证 人员变更手续和变 更人员资格 相关审查、检查资 料与工作记录 安全文明施工费 项目经理安管职 责履行 施工单位资质 安全生产许可 违法分包 转包 施工单位人员变 更 施工单位变更 既有建(构)筑 物或管线安全管 理 轨道工程关键节 点风险管控 施 工 单 位 (一) □ □ □ □ □ □ □ □ □ □ 9 10 11 12 13 14 □符合 □符合 □符合 □符合 □符合 □符合 □符合 二、施工单位安全生产重点行为 检查情况 □符合 □符合 5 6 7 8 第 2 页,共 6 页

分类:风险评估 行业:建筑加工行业 文件类型:Excel 文件大小:43.5 KB 时间:2025-10-02 价格:¥2.00

风险隐患表格清单-现场类消防专项隐患排查表(每季度一次)

排查日期: 编 号 名称 排查项目 危险源或潜在事件(标准) 应急照明情况 应急照明有效运转亮度达到要求 工程 技术 设置应急照明灯 应急照明情况 应急照明有效运转亮度达到要求 安全 管理 加强检查,定期维护保养 消防器材情况 消防器材配备合理定期检验有效 好用 工程 技术 配备二氧化碳灭火器 消防器材情况 消防器材配备合理定期检验有效 好用 安全 管理 加强检查,定期维护保养 消防器材情况 消防器材配备合理定期检验有效 好用 应急 处置 发生火灾事故立即启动应急预案 耐火等级 厂房建筑物符合耐火等级符合要 求;建筑物的安全疏散门向外开 启;甲、乙、丙类厂房的安全疏 散门不应少于两个(面积小于 60m2的乙B、丙类液体设备的房间 可设1个),安全通道、疏散门通 畅 工程 技术 按照消防要求采用外开防火门 耐火等级 厂房建筑物符合耐火等级符合要 求;建筑物的安全疏散门向外开 启;甲、乙、丙类厂房的安全疏 散门不应少于两个(面积小于 60m2的乙B、丙类液体设备的房间 可设2个),安全通道、疏散门通 畅 安全 管理 每季度进行一次消防检查 堆放情况 仓库、场地堆放货物留有规定的 安全通道和间距,存放的货物无 倾斜、倒塌等危险堆垛。 安全 管理 按要求进行对方,留足安全通道,加强监督 检查 消防设施 仓库消防预警装置。充足的消防 水源,周围堆放货物。仓库、堆 场的灭火机器置符合规定要求。 仓库、堆场火源和火种监控措施 及手段;整个仓库、堆场安装避 雷装置,检验合格有效。 安全 管理 每季度检查维护一次消防设施 消防设施 仓库消防预警装置。充足的消防 水源,周围堆放货物。仓库、堆 场的灭火机器置符合规定要求。 仓库、堆场火源和火种监控措施 及手段;整个仓库、堆场安装避 雷装置,检验合格有效。 应急 处置 一旦着火,就近采用消防设施进行灭火 应急物资 防洪防汛、防高温、防中毒、防 火灾等应急物资充足,抢险队伍 定期演练,配备沙袋、铁锨、排 水泵、灭火器、水带、空气呼吸 器、备用气瓶、防毒面罩、防毒 口罩、风机、风扇、茶叶、风油 精以及医疗救护箱等。 工程 技术 采购合格的物资 应急物资 防洪防汛、防高温、防中毒、防 火灾等应急物资充足,抢险队伍 定期演练,配备沙袋、铁锨、排 水泵、灭火器、水带、空气呼吸 器、备用气瓶、防毒面罩、防毒 口罩、风机、风扇、茶叶、风油 精以及医疗救护箱等。 安全 管理 每季度检查一次应急物资储备情况,设置专 人进行管理,及时的进行维护更换 消防图纸 有消防水源图、标明消防栓的具 体位置 安全 管理 设置档案柜专门进行存储 消防水源 消火栓出水测试水压符合相关标 准要求,消防水池水量符合要求 安全 管理 每季度检查一次消防水情况,制定消防管理 制度和应急预案 消防水源 消火栓出水测试水压符合相关标 准要求,消防水池水量符合要求 教育 培训 培训消防管理制度和应急预案 消防水压 喷淋系统末端放水测试水压正 常,能直接启动喷淋泵,水流指 示器信号回馈正常,有防腐保温 等措施 工程 技术 更换规格符合要求的备品备件 排查 情况 (是 存在问题 2 3 4 变配 电室 厂房 建筑 仓库 堆场 消防 设施 消防专项隐患排查表 排查人员: 风险点 排查内容 管控措施 1 消防水压 喷淋系统末端放水测试水压正 常,能直接启动喷淋泵,水流指 示器信号回馈正常,有防腐保温 等措施 安全 管理 每季度检查一次,测试一次 消防水泵 消火栓泵、喷淋泵主、备泵手动 启动正常 安全 管理 每季度检查一次,测试一次 火灾报警 火灾手动自动报警器、警报器正 常 安全 管理 每季度检查一次,测试一次 消防电源 主、备电源切换正常 安全 管理 每季度检查一次,测试一次 防火卷帘 防火卷帘等能正常联动,应急照 明、应急疏散标志正常好用 安全 管理 每季度检查一次,测试一次 消防器材 按规定配置消防器材,消防器材 设置位置应在明显、便于取用的 地点,放置位置合理,不能埋压 、遮挡灭火器材 安全 管理 每季度检查一次,测试一次 日常管理 专人维护管理,保证消防设施、 器材的正常、有效使用,外观完 好、附件齐全、压力正常在有效 期内,定期组织消防演练 安全 管理 每季度检查一次,测试一次 按应急预案的要求配备应急物资 及装备(根据有限空间作业的特 点配备相关的呼吸器、防毒面罩 、通讯设备、安全绳索等应急装 备 和 器 材 ) , 建 立 使 用 状 况 档 案,定期检测和维护,使其处于 良好状态 安全 管理 / 建立应急值守制度,设定应急值 守人员,保障报警电话24小时畅 通 安全 管理 / 消防栓、灭火器失效或未按规定 配置。 工程 技术 配置符合要求的消防器材 消防栓、灭火器失效或未按规定 配置。 安全 管理 加强管理,按规定配置消防栓、灭火器并定 期检查。 消防栓、灭火器失效或未按规定 配置。 应急 处置 发现火灾第一时间进行报警,采用就近灭火 器进行扑救 违规使用明火 安全 管理 加强现场监督检查和考核 现场动火作业未办理作业票证未 采取相关措施 安全 管理 按规定进行作业审批,落实安全措施 现场存在电气起火隐患 工程 技术 使用符合要求的电气设备 现场存在电气起火隐患 安全 管理 加强现场监督检查 疏散通道不畅通 工程 技术 设置疏散路线图 疏散通道不畅通 安全 管理 加强现场监督检查 应急照明缺失或不正常使用 工程 技术 设置符合要求的应急照明灯 应急照明缺失或不正常使用 安全 管理 加强现场监督检查 场内废纸堆积过高。 安全 管理 严格按要求堆积废纸,严禁过高堆放。 场内废纸堆积过高。 个体 防护 佩戴劳动防护用品。 场内高处平台未按规定设置防护 栏。 工程 技术 高处平台按规定设置防护栏。 防火 巡查 应急救援管理 每班不间断无死角 巡查车间废纸场的 安全情况并做好巡 查记录。 4 5 6 消防 设施 管理

分类:风险评估 行业:其它行业 文件类型:Excel 文件大小:24.5 KB 时间:2025-10-03 价格:¥2.00

建筑施工事故应急处理预案

建筑施工事故应急处理预案 为贯彻落实国家安全生产的法律法规及《建筑法》第四十四条和五十一 条关于安全生产的有关规定,促进企业依法加强对建筑安全生产的管理,执 行安全生产责任制度,采取有效措施,防止伤亡和其他安全生产事故的发生, 以及当施工中发生事故时,企业能采取紧急措施减少人员伤亡和事故损失, 根据柳州市政府和市建委的要求,并结合企业的特点,特制定本企业的建筑 施工事故应急处理预案。 一、指导思想 为了保证建筑施工事故应急处理措施的及时性和有效性,本着“预防为 主、自救为主、统一指挥、分工负责”的原则,充分发挥企业在事故应急处 理中的重要作用,保障企业、社会及人民生命财产的安全,使事故造成的损 失和影响降至最低程度。 二、建筑施工的主要特点及事故隐患的分布 建筑施工是一个技术复杂,隐患众多,事故多发的行业,它有与工矿企 业明显的不同特点: 1、产品(建筑物、构筑物)形式多样,很难实现标准化。结构、外形多 变,施工方法必将随之改变。 2、产品位置固定,生产活动都是围绕着建筑物、构筑物来进行的,这就 形成了在有限的场地上集中了大量的工人、建筑材料、设备和施工机具进行 作业,而且各种机械设备、施工人员都要随着施工的进展而不停的流动,作 业条件随之变换,不安全因素随时可能出现。 3、产品点多、面广,施工流动性大,这给施工管理增加了困难。 4、产品高、大、深,露天高空作业多,施工周期长;施工人员在室外露 天作业,工作条件差危险因素多。 5、建筑结构复杂,工艺变化大,规则性差。每栋建筑物从基础、主体到 装修,每道工序不同,不安全因素也不同,即使同一道工序由于工艺和施工 方法不同,生产过程也不同。而随着工程进度的发展,施工现场的状况和不 安全因素也随着变化。 6、手工操作为主,机械化程度低。 可见,建筑施工是一个特殊的、复杂的生产过程,是一个各种因素多变 的生产过程,存在的危险因素甚多,因此,建筑业是一个事故多发的行业。 据全国伤亡事故统计,建筑业伤亡事故率仅次于矿山行业。 通过对事故的类别、原因、发生的部位等进行的统计分析得知,高处坠落、 触电事故、物体打击、机械伤害、坍塌事故等五种是建筑业最常发生的事故, 占事故总数的 85%以上,因此,这五种事故称为“五大伤害”。此外,中毒和 火灾也是多发性事故,所以,我们在日常生产活动中要加强对以上多发性事 故隐患的整治工作,采取有效措施,防止发生事故。 三、组织机构的设置和分工 (一)成立应急指挥领导小组 1、领导小组成员名单 组 长: 副 组 长: 成 员: 2、设领导小组办公室(办公室设在公司质安处) 办公室主任: 办公室成员: 办公室电话: (二)成立施工现场应急救援小组 每个工程项目开工时,由项目部全体管理人员组成施工现场应急救援小 组,项目经理任小组长。每个小组需配备一名经过培训的卫生急救人员和保 健医药箱及必需的急救器材。

分类:事故与应急 行业:建筑加工行业 文件类型:Word 文件大小:39.5 KB 时间:2025-10-25 价格:¥2.00

涵洞施工安全交底签证表

安全交底签证表 工程名称 杭瑞国家高速公路湖南省岳阳至常德公 路 交底编号 交底里程 K62+755 交底项目 涵洞施工安全技 术 一、一般要求 1、现场施工人员必须佩戴安全帽,电焊工工作时必须佩戴眼镜。 2、基坑开挖时放坡不小于 1:1,若交底另有要求,严格按交底执行;若因现场 条件限制放坡不足时应设置足够牢固的支挡设施。开挖出的弃土离基坑边堆放 距离至少应大于 1m,且堆放高度不超过 2m。开挖完成后,应在基坑四周设置防 护栏杆及醒目标志牌,非施工人员不得靠近。 3、配电箱以及其它供电设备不得置于水中,电线接头要牢固,并且要绝缘, 输电线路必须设有漏电开关。 4、挖掘机及吊车工作时,必须有专人指挥,并且在其工作范围内不得站人。 5、砼运输车进出场必须打开转向灯,入场后倒车必须设设专人指挥。 6、吊车、挖掘机等机械工作之前必须进行机械安全检查。 7、施工作业平台必须规整平顺,杂物必须清除干净;现场卸料前,必须检查 卸料方向是否有人,以避免将人员砸伤。 8、夜间施工,注意照明安全、交通安全、超重安全、用电安全几项措施,夜 间施工有值班领导在场。 9、严禁疲劳施工、要严格执行安全管理制度,每个工作面最少安排 2 组工作 组,每班工作组施工人员每天上岗不得超过 8 小时,以免造成意外事故。 二、焊接安全要点 1、焊接设备上的电机、电器等应有完整的防护外壳,一、二次接线柱处应有保护罩。 2、现场使用的电焊机应设有可防雨、防潮、防晒的机棚,并备有消防用品。 3、焊接时,焊接和配合人员必须采取防止触电、高空坠落、瓦斯中毒和火灾 等事故的安全措施。 4、接地线及手把线都不得搭在易燃易爆和带有热源的物品上,接地线不得接 在管道和建筑物金属构件上,接地电阻不大于 4Ω。 5、 雨天不得露天电焊,在潮湿地带作业时,操作人员应站在铺有绝缘物品的 地方并穿好绝缘鞋。 6、烛钳应与手把线连接牢固,不得用胳膊夹持焊钳。清除焊渣时,面部应避 开被清的焊缝。 7、施焊现场 10m 范围内,不得堆放氧气瓶、乙炔发生器、木材等易燃易爆 物。 8、作业后,清理场地、灭绝火种,切断电源,销好电闸箱,消除烟云料余热 后,方可离开。 三、施工用电注意事项 1、施工现场所有电气设备的胶皮线及其绝缘性能必须保持良好;凡是裸露带电部位的电 气设备和易发生电击危险的区域,设置安全警示标志,严禁乱接电线,手持式用电设备应 该配置漏电保护器。 2、临时供电线路,应用瓷夹固定,保险丝应按用电负荷配置,动力线路不得使用裸线, 电气设备的金属外壳及支架配电盘等,均应有可靠的接地装置,露天设置的所有闸刀开 关,设在闸刀箱内加锁,闸刀箱设遮雨棚。 3、凡是裸露带电部位的电气设备和易发生电击危险的区域,设置安全警示标志。夜间施 工应设置足够的照明设备,应使用防爆灯。 四、吊装作业安全注意事项 1、起重工必须经专门安全技术培训,考试合格持证上岗。严禁酒后作业。 2、起重机作业时必须确定吊装区域,并设警戒标志,必要时派人监护。作业时必须正确 选择吊点的位置,合理穿挂索具,试吊。除指挥及挂钩人员外,严禁其他人员进入吊装作 业区。 3、恶劣气候如大雨、大雾和施工作业面有六级(含六级)以上的强风影响安全施工时应暂 停吊装作业;起重机发生漏电现象应暂停吊装作业;钢丝绳严重磨损,达到报废标准时应 暂停吊装作业;安全保护装置失效或显示不准确时应暂停吊装作业。 4、作业前必须检查作业环境、吊索具、防护用品。吊装区域无闲散人员,障碍已排除。 吊索具无缺陷,捆绑正确牢固,被吊物与其他物件无连接。确认安全后方可作业。

分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:26.1 KB 时间:2025-10-28 价格:¥2.00

005 施工项目应急处置流程告知卡汇编

目录 1. 火灾事故现场应急处置方案......................................................................................................2 2. 触电事故现场应急处置方案......................................................................................................4 3. 高处坠落事故现场应急处置方案..............................................................................................6 4. 群体食物中毒现场应急处置方案..............................................................................................8 5. 交通事故现场应急处置方案....................................................................................................10 6. 机械伤害事故现场应急处置方案............................................................................................12 7. 中暑现场应急处置方案............................................................................................................14 8. 物体打击事故现场应急处置方案............................................................................................16 9. 突发疾病现场应急处置方案....................................................................................................18 10. 灼伤事故现场应急处置方案..................................................................................................20 11. 塌方(坍塌)事故现场应急处置方案..................................................................................22 12. 脚手架事故现场应急处置方案..............................................................................................24 13 地质灾害现场应急处置方案....................................................................................................26 14. 恶劣天气现场应急处置方案..................................................................................................28 15. 洪水灾害现场应急处置方案..................................................................................................30 16. 环境污染事件应急处置方案..................................................................................................32 17. 输电线路上作业人员遭遇雷电事故现场应急处置方案......................................................34 18. 溺水事件应急处置方案..........................................................................................................36 19. 人身伤亡事故现场应急处置方案..........................................................................................38 20. 急性传染病现场应急处置方案..............................................................................................41 1. 火灾事故现场应急处置方案 火灾事故现场应急处置方案 事故 特征 事故类型:气体火灾、液体灾害、固体可燃物火灾。 危害程度:火灾生成的有毒、有害或窒息性气体易使人员中毒或缺氧窒息死亡,燃 烧的火焰会造成人员烧伤或死亡。 事故征兆:焦糊味、烟、火光、电气产品突然损坏或温度异常升高、线路产生火花。 发生条件:有可燃物,有氧气或氧化剂,有热源。 应急 组织 及职 责 组长:,联系方式:xx 职责:负责指挥灭火和人员财产的抢救工作,向各职能组下达抢救指令任务,根据 火灾情况判断是否向 119、120 等有关部门报告和求援。 副组长:xx,联系方式:xx 职责:协调各组之间的抢救工作,协助组长指挥现场应急救援工作,组长不在现场时, 承担指挥职责。 成员:安全部:xx,联系方式: xx 职责:负责现场处置 物资供应:xx ,联系方式: xx 职责:负责抢险、救援物资、器材器具的供应。 综合办公室:xx,联系方式: xx 职责:负责报告公司总部及相关单位,根据组长指令向 119、120 求援,负责安排车 辆。 现场安全保卫:各工区主任及现场技术员 职责:负责组织消防人员进行火灾扑救,物资抢救,对事故现场划定警戒区,阻止 与救援无关人员进入现场。 应急 处置 程序 1. 现场人员第一时间报警,及时通知现场负责人。 2. 现场负责人、现场处置小组成员接到报告应立即联系各应急处置部门及时赶到 火灾地点。 3. 组长到达现场后应根据火情,按照应急处置措施组织义务消防队和现场施工人 员进行自救。 4. 火灾事故超出应急能力时,向当地政府及上级主管部门请求支援。 应急 处置 措施 1.最先发现火情的人要大声呼叫,某某地点或某某部位失火,并报告单位负责人。向 内部报警时,报警人员应叙述:出事地点、情况、报警人姓名;向外部报警时,报警 人应详细准确报告:出事地点、单位、电话、事态现状及报告人姓名、单位、地址、 电话;报警完毕报警员应到路口迎接消防车及急救人员的到来。 2.现场负责人负责现场总指挥。打电话通知 119 报告失火地点,火势以及联系人和联 系电话,同时通知主管领导。 3.按应急方案立即进行自救。火灾初起阶段可用灭火器灭火,用消防桶提水,用铁锹 铲土等力争在火灾初起阶段,将火扑灭。若事态严重,难以控制和处理,应在自救 的同时向专业救援队求助。 4.由电工负责切断电源,防止事态扩大。 5.在组织扑救的同时,组织人员清理、疏散现场人员和易燃易爆、可燃材料。如有物

分类:事故与应急 行业:建筑加工行业 文件类型:Word 文件大小:207 KB 时间:2025-10-28 价格:¥2.00

危险源辨识与评价清单-OHS危险源辨识与评价清单(工程部1227)

OHS 危险源辨识与评价清单 部门: 工程部、施工单位 编号: CDCSG-QR10-03/A 危险评价 序 号 作业活动 危险源 可能导致的事故 时态 状态 L E C D 危险 级别 备注 1 临边防护不稳定,部分基坑缺少防护,未设警示标 志 高处坠落 将来 异常 3 3 7 63 一般 2 作业人员上下基坑没有设置斜道 高处坠落 将来 异常 1 3 7 21 一般 3 基坑上下人员的斜道扶手不符合安全要求(没有设 防滑条或防护栏杆高度不够) 高处坠落 将来 异常 1 3 7 21 一般 4 拉土方车辆在施工场地的行驶对作业人员的危害 车辆伤害 将来 正常 1 3 15 45 一般 5 土方作业前施工人员没有对作业人员进行安全交底 机械伤害、高处坠落 将来 异常 3 1 15 45 一般 6 施工作业人员没有经过培训,无证上岗 机械伤害/高处坠落等 将来 异常 1 0.5 40 20 一般 7 无安全技术措施施工方案 高处坠落/物体打击/触 电 将来 正常 1 6 15 90 一般 8 挖掘机工作中对周围作业人员的伤害 机械伤害 将来 正常 3 1 15 45 一般 9 开挖深度超过 2 米的沟槽,未按标准设围栏防护和 密目网封挡 坍塌/高处坠落 将来 正常 3 6 3 54 一般 10 超过 2 米的沟槽未搭设上下马道,危险处无红色标 志灯 坍塌/高处坠落 将来 正常 3 6 1 18 一般 11 在沟、坑、槽边 1.5 米以内堆土堆料、停置机具 坍塌 将来 正常 1 1 7 7 一般 12 深坑基础护壁不符合规定 坍塌 将来 正常 3 6 7 126 一般 13 机械设备施工与槽边安全距离不符合规定,又无措 施 坍塌 现在 正常 3 1 15 45 一般 14 基坑施工 未设置有效的排水和挡水措施 坍塌 现在 正常 3 6 1 18 一般 15 施工安全防护栏杆 高处坠落 现在 正常 3 3 15 135 一般 16 土方施工时放坡不符合规定 坍塌/高处坠落 过去 正常 3 6 7 126 一般 17 未按规定设置安全标志 物体打击 现在 正常 3 6 1 18 一般 18 铁凳、木凳不稳固,跳板下支凳间距大于 2 米 高处坠落 现在 正常 3 6 3 54 一般 19 外檐进行立体交叉作业时,在同一垂直方向操作, 未采取隔离防护措施 高处坠落 现在 正常 3 2 7 42 一般 20 框架结构作用面、点无防护或防护不完善 高处坠落 现在 正常 3 2 15 90 一般 21 坡屋面施工无防护栏杆,未系安全带 高处坠落 将来 正常 3 6 15 270 重大 22 吊运零散物件未使用吊笼 物体打击 现在 正常 1 2 7 14 一般 23 外挑平台堆料超高、超重 物体打击 现在 正常 3 2 15 90 一般 24 高空作业 抛、扔物品违反安全操作规程 高处坠落 现在 异常 3 2 7 42 一般 25 未采用 TN-S 接零保护系统 物体打击 现在 正常 6 6 3 108 一般 26 供电系统未按三级配电两级保护进行安装 触电 将来 异常 3 2 15 90 一般 27 在使用同一供电系统时,缺少设备保护接零,缺少 保护接地 触电 现在 正常 6 6 3 108 一般 28 拆除、拆除时撬杆用力过猛 高空坠落 现在 正常 6 6 3 108 一般 29 保护接地、保护接零混乱或共存 触电 过去 正常 3 2 15 90 一般 30 保护零线装设开关或熔断器,零线有拧缠式接头 触电 将来 正常 1 2 7 14 一般 31 保护零线未单独敷设或作他用 触电 将来 正常 1 2 7 14 一般 32 施工用电 使用绿/黄双色线作负荷线 触电 将来 异常 3 2 7 42 一般 33 焊渣引起明火 火灾 现在 异常 3 1 7 21 一般 34 电焊机未按“四一”要求设置 触电 过去 正常 3 1 7 21 一般 35 电焊机一次线长度大于 5 米二次线大于 30 米,两侧 接线不牢 触电 过去 正常 3 3 15 135 一般 36 电焊作业 电焊机一/二次线未安装防护罩,防触电装置 触电 过去 正常 3 2 7 42 一般

分类:安全管理制度 行业:建筑加工行业 文件类型:Word 文件大小:126 KB 时间:2025-11-18 价格:¥2.00

生产安全事故应急预案-深基坑施工应急预案

立交桥泵站深基坑施工应急预案 一、应急预案的方针与原则 坚持“安全第一,预防为主”、“保护人员安全优先,保护环境优先” 的方针,贯彻“常备不懈、统一指挥、高效协调、持续改进”的原则。更 好地适应法律和经济活动的要求;给企业员工的工作和施工场区周围居民 提供更好更安全的环境;保证各种应急资源处于良好的备战状态;指导应 急行动按计划有序地进行;防止因应急行动组织不力或现场救援工作的无 序和混乱而延误事故的应急救援;有效地避免或降低人员伤亡和财产损失; 帮助实现应急行动的快速、有序、高效;充分体现应急救援的“应急精神”。 二、应急策划 (一)工程概况及地质条件 (1)工程概况 济南市城区工程建设指挥部拟在经十路南侧、铁西路东侧修建一座泵 房站,建筑物长 22.00 米,宽度 2.8-11.5 米,基坑开挖深度 12.00 米, 根据场地工程地质及水文地质条件,在基坑开挖和使用过程中需要进行临 时性基坑支护。 (2)工程地质 1、岩土工程条件 拟建场地地形平坦,地貌单元为山前冲洪积平原下部,场区内与基坑 支护工程有关的底层主要为上部的填土及下部的冲洪积粉土和粘性土。 层号 岩土名称 平均厚度 (m) 重度(KN/m3) 内聚力 (Kpa) 内摩擦角 (0) 1 杂填土及素填土 7.10 19.10 19.00 13.00 2 粉土 2.00 19.50 14.00 15.70 3 粘土 1.40 19.50 30.00 14.00 4 粉质粘土 1.80 19.00 35.00 19.00 5 粉土、粉质粘土 6.00 19.50 32.00 18.00 2、水文地质条件 场区地下水类型为第四系孔隙潜水,勘察期间正值丰水季节,水位埋 深 5.00 米,对砼无腐蚀性。 3、周边环境条件 根据业主提供的平面图及现场资料,基坑周边场地相对开阔,距离周 边道路及已建建筑物约为 9.8m-14.50m,基坑安全登记按二级考虑。 (二)深基坑施工方案及支护方案 1、支护方案总说明 根据本工程的岩土工程条件,水文地质特点和周围环境情况,结合当 地经验,并经综合计算分析确定,对地下水采用坑外搅拌桩形成止水帷幕, 坑内管井降水的综合方法进行控制,对于支护结构,AB 及 CD 段采用桩加内 支撑方法支护,其他部位采用桩锚支护方法。 2、地下水控制: 因基坑支护影响范围内地基土较软弱,基坑开挖较深,周围道路及已 建建筑物距基坑的距离基本都在一倍基坑深度左右,为保证在有效控制地 下水的同时,避免对周围建筑物的影响,决定基坑周围采用一排搅拌桩形 成止水帷幕挡水,坑内采用管井降水的方法处理地下水。 粉喷桩埋头 4.50m,桩长 13.50m,桩间距 0.35 m,临桩搭接 0.15 m,水 泥掺入量为 0.15。降水井布置 4 眼,设计井深 18.00 m(自现地面算起), 成孔直径 800 m m,滤水管采用内径 400mm,外径 500mm 的无砂水泥滤管,填 料采用φ0.5 碎石,滤网可采用纱网。 3、支护方案 依据岩土工程条件,结合基坑平面形状复杂,开挖较深,作业范围狭 小的特点,决定上部 4.50m 深度范围内采用 450 放坡,下部采用桩锚和桩加 内支撑的联合方法进行支护。 3.1 桩锚支护 本支护单元坡顶 2.00m 以外考虑 5.00m 宽,15Kpa 局部荷载,有关桩锚 支护的主要设计内容如下: 支护桩: 名称 桩顶标 高(米) 直 径 (mm) 间 距 (mm) 长 度 (mm) 配筋 钻孔灌注桩 -4.5 800 1200 13500 纵筋11φ25,箍筋φ8◎200,加强筋φ 14◎2000 锚杆 自由长度(米) 序号 标 高 (米) 直 径 (mm) 自由段 锚固段 拉筋(钢 绞线) 设计拉力 (KN) 锁定拉力 (KN) 备注 锚杆 1 -6.50 150 5.00 17.00 4-7φ5 300 180

分类:事故与应急 行业:其它行业 文件类型:Word 文件大小:82.5 KB 时间:2025-12-04 价格:¥2.00

现场类消防专项隐患排查表(每季度一次)

排查日期: 编 号 名称 排查项目 危险源或潜在事件(标准) 应急照明情况 应急照明有效运转亮度达到要求 工程 技术 设置应急照明灯 应急照明情况 应急照明有效运转亮度达到要求 安全 管理 加强检查,定期维护保养 消防器材情况 消防器材配备合理定期检验有效 好用 工程 技术 配备二氧化碳灭火器 消防器材情况 消防器材配备合理定期检验有效 好用 安全 管理 加强检查,定期维护保养 消防器材情况 消防器材配备合理定期检验有效 好用 应急 处置 发生火灾事故立即启动应急预案 耐火等级 厂房建筑物符合耐火等级符合要 求;建筑物的安全疏散门向外开 启;甲、乙、丙类厂房的安全疏 散门不应少于两个(面积小于 60m2的乙B、丙类液体设备的房间 可设1个),安全通道、疏散门通 畅 工程 技术 按照消防要求采用外开防火门 耐火等级 厂房建筑物符合耐火等级符合要 求;建筑物的安全疏散门向外开 启;甲、乙、丙类厂房的安全疏 散门不应少于两个(面积小于 60m2的乙B、丙类液体设备的房间 可设2个),安全通道、疏散门通 畅 安全 管理 每季度进行一次消防检查 堆放情况 仓库、场地堆放货物留有规定的 安全通道和间距,存放的货物无 倾斜、倒塌等危险堆垛。 安全 管理 按要求进行对方,留足安全通道,加强监督 检查 消防设施 仓库消防预警装置。充足的消防 水源,周围堆放货物。仓库、堆 场的灭火机器置符合规定要求。 仓库、堆场火源和火种监控措施 及手段;整个仓库、堆场安装避 雷装置,检验合格有效。 安全 管理 每季度检查维护一次消防设施 消防设施 仓库消防预警装置。充足的消防 水源,周围堆放货物。仓库、堆 场的灭火机器置符合规定要求。 仓库、堆场火源和火种监控措施 及手段;整个仓库、堆场安装避 雷装置,检验合格有效。 应急 处置 一旦着火,就近采用消防设施进行灭火 应急物资 防洪防汛、防高温、防中毒、防 火灾等应急物资充足,抢险队伍 定期演练,配备沙袋、铁锨、排 水泵、灭火器、水带、空气呼吸 器、备用气瓶、防毒面罩、防毒 口罩、风机、风扇、茶叶、风油 精以及医疗救护箱等。 工程 技术 采购合格的物资 应急物资 防洪防汛、防高温、防中毒、防 火灾等应急物资充足,抢险队伍 定期演练,配备沙袋、铁锨、排 水泵、灭火器、水带、空气呼吸 器、备用气瓶、防毒面罩、防毒 口罩、风机、风扇、茶叶、风油 精以及医疗救护箱等。 安全 管理 每季度检查一次应急物资储备情况,设置专 人进行管理,及时的进行维护更换 消防图纸 有消防水源图、标明消防栓的具 体位置 安全 管理 设置档案柜专门进行存储 消防水源 消火栓出水测试水压符合相关标 准要求,消防水池水量符合要求 安全 管理 每季度检查一次消防水情况,制定消防管理 制度和应急预案 消防水源 消火栓出水测试水压符合相关标 准要求,消防水池水量符合要求 教育 培训 培训消防管理制度和应急预案 消防水压 喷淋系统末端放水测试水压正 常,能直接启动喷淋泵,水流指 示器信号回馈正常,有防腐保温 等措施 工程 技术 更换规格符合要求的备品备件 排查 情况 (是 存在问题 2 3 4 变配 电室 厂房 建筑 仓库 堆场 消防 设施 消防专项隐患排查表 排查人员: 风险点 排查内容 管控措施 1 消防水压 喷淋系统末端放水测试水压正 常,能直接启动喷淋泵,水流指 示器信号回馈正常,有防腐保温 等措施 安全 管理 每季度检查一次,测试一次 消防水泵 消火栓泵、喷淋泵主、备泵手动 启动正常 安全 管理 每季度检查一次,测试一次 火灾报警 火灾手动自动报警器、警报器正 常 安全 管理 每季度检查一次,测试一次 消防电源 主、备电源切换正常 安全 管理 每季度检查一次,测试一次 防火卷帘 防火卷帘等能正常联动,应急照 明、应急疏散标志正常好用 安全 管理 每季度检查一次,测试一次 消防器材 按规定配置消防器材,消防器材 设置位置应在明显、便于取用的 地点,放置位置合理,不能埋压 、遮挡灭火器材 安全 管理 每季度检查一次,测试一次 日常管理 专人维护管理,保证消防设施、 器材的正常、有效使用,外观完 好、附件齐全、压力正常在有效 期内,定期组织消防演练 安全 管理 每季度检查一次,测试一次 按应急预案的要求配备应急物资 及装备(根据有限空间作业的特 点配备相关的呼吸器、防毒面罩 、通讯设备、安全绳索等应急装 备 和 器 材 ) , 建 立 使 用 状 况 档 案,定期检测和维护,使其处于 良好状态 安全 管理 / 建立应急值守制度,设定应急值 守人员,保障报警电话24小时畅 通 安全 管理 / 消防栓、灭火器失效或未按规定 配置。 工程 技术 配置符合要求的消防器材 消防栓、灭火器失效或未按规定 配置。 安全 管理 加强管理,按规定配置消防栓、灭火器并定 期检查。 消防栓、灭火器失效或未按规定 配置。 应急 处置 发现火灾第一时间进行报警,采用就近灭火 器进行扑救 违规使用明火 安全 管理 加强现场监督检查和考核 现场动火作业未办理作业票证未 采取相关措施 安全 管理 按规定进行作业审批,落实安全措施 现场存在电气起火隐患 工程 技术 使用符合要求的电气设备 现场存在电气起火隐患 安全 管理 加强现场监督检查 疏散通道不畅通 工程 技术 设置疏散路线图 疏散通道不畅通 安全 管理 加强现场监督检查 应急照明缺失或不正常使用 工程 技术 设置符合要求的应急照明灯 应急照明缺失或不正常使用 安全 管理 加强现场监督检查 场内废纸堆积过高。 安全 管理 严格按要求堆积废纸,严禁过高堆放。 场内废纸堆积过高。 个体 防护 佩戴劳动防护用品。 场内高处平台未按规定设置防护 栏。 工程 技术 高处平台按规定设置防护栏。 防火 巡查 应急救援管理 每班不间断无死角 巡查车间废纸场的 安全情况并做好巡 查记录。 4 5 6 消防 设施 管理

分类:安全管理制度 行业:其它行业 文件类型:Excel 文件大小:24.5 KB 时间:2025-12-13 价格:¥2.00

施工机具检查评分表GDAQ2030118

序 号 检查项目合计 年 月 日 100 3 97 检查人员: 10 打桩机械 打桩机安装后无验收合格手续的,扣5分 10 0 10 打桩机无超高限位装置的,扣5分 打桩机行走路线地耐力不符合说明书要求的,扣5分 打桩作业无方案的,扣5分 打桩操作违反操作规程的,扣5分 9 潜水泵 未做保护接零、无漏电保护器的,各扣5分 10 0 10 保护装置不灵敏、使用不合理的,扣5分 8 翻斗车 翻斗车制动装置不灵敏的,扣5分 10 0 10 无证司机驾车的,扣5分 行车载人或违章行车的,每发现一次,扣5分 7 气 瓶 各种气瓶无标准色标的,扣5分 10 0 10 气瓶间距小于5m、距明火小于10m又无隔离措施的,各扣5分 乙炔瓶使用或存放时平放的,扣5分 气瓶存放不符合要求的,扣5分 气瓶无防震圈、防护帽的,每一个扣2分 0 10 未做保护接零、无漏电保护器的,各扣5分 离合器、制动器、钢丝绳达不到要求的,每项扣3分 操作手柄无保险装置的,扣3分 搅拌机无防雨棚和作业台不安全的,扣4分 料斗无保险挂钩或挂钩不使用的,扣3分 传动部位无防护罩的,扣4分 作业平台不平稳的,扣3分 焊把线接头超过3处或绝缘老化的,扣5分 电焊机无防雨罩的,扣4分 6 搅拌机 搅拌机安装后无验收合格手续的,扣5分 10 5 电焊机 电焊机安装后无验收合格手续的,扣5分 10 0 10 未做保护接零、无漏电保护器的,各扣5分 无二次空载降压保护器或无触电保护器的,扣5分 一次线长度超过规定或不穿管保护的,扣5分 电源不使用自动开关的,扣3分 4 钢筋机械 机械安装后无验收合格手续的,扣5分 10 3 7 未做保护接零、无漏电保护器的,各扣5分 钢筋冷拉作业区及对焊作业区无防护措施的,扣5分 传动部位无防护的,扣3分 3 手持电动工具 Ⅰ类手持电动工具无保护接零的,扣10分 10 0 10 使用Ⅰ类手持电动工具不按规定穿戴绝缘用品的,扣5分 使用手持电动工具随意接长电源线或更换插头的,扣5分 0 10 无锯盘护罩、分料器、防护挡板安全装置和传动部位无防护, 未做保护接零、无漏电保护器的,各扣5分 无人操作时未切断电源的,扣3分 使用平刨和圆盘锯合用一台电机的多功能木工机具的,平刨和 2 圆盘电锯 电锯安装后无验收合格手续的,扣5分 10 1 平 刨 平刨安装后无验收合格手续的,扣5分 10 0 10 无护手安全装置的,扣5分 传动部位无防护罩的,扣5分 未做保护接零、无漏电保护器的,各扣5分 无人操作时未切断电源的,扣3分 施工机具检查评分表 GDAQ2030118 JGJ 59—99 表3.0.13 检查项目 扣 分 标 准 应得 分数 扣减 分数 实得 分数

分类:安全管理制度 行业:其它行业 文件类型:Excel 文件大小:27.5 KB 时间:2025-12-15 价格:¥2.00

工程危险因素识别评价表(民用建筑部分)

1 工 程 处 危 险 因 素 识 别 评 价 表 ( 民 用 建 筑 部 分 ) 编号: 危 险 因 素 识 别 作业条件危险性评价 序 号 作业活动 序 号 因 素 类 别 可能导致的 事 故 判别依 据(Ⅰ- Ⅴ) L E C D 危险 级别 现有控制措施 备注 1. 1 临建用电私接乱设 违章作业 触电 Ⅲ 3 2 15 90 显著 现场监督检查 2. 2 三通一平工作中生活用水不到位 管理缺陷 疫情 Ⅰ 1 1 7 7 稍有 按规定审核把关 3. 一、施工准 备阶段 3 机械施工设备进场无计划 管理缺陷 机械伤害 Ⅱ 3 3 7 42 一般 按方案检查把关 4. 1 土方施工安全方案 管理缺陷 坍塌 Ⅱ 3 1 15 45 一般 按规定审核把关 5. 2 土方开挖无安全技术交底 管理缺陷 坍塌 Ⅱ 3 1 15 45 一般 按规定审核把关 6. 3 违反土方开挖操作程序,掏挖、反坡作 业 违章操作 坍塌 Ⅲ 3 3 15 135 显著 现场监督检查 7. 4 坑沟边机械挖土,坑内支护强度不够, 或碰坏支撑 违章作业 坍塌 Ⅰ 1 1 15 15 稍有 审核把关,现场监督检查 8. 5 基础沉箱护壁强度不够 设施沉陷 坍塌 Ⅱ 1 2 15 30 一般 按方案检查把关 9. 6 土方施工时未按规定放坡 防护缺陷 坍塌 Ⅲ 3 2 15 90 显著 按方案检查把关 10. 7 开挖深度超过 2 米的沟槽,未按标准设 置围栏防护和密目安全网封挡不严 防护缺陷 高处坠落 Ⅱ 3 6 3 54 一般 现场检查把关 11. 8 超过 2 米的沟槽未搭设上下通道,危险 处未设红色标志灯 防 护 缺 陷 信号缺陷 高处坠落 Ⅱ 3 6 3 54 一般 现场检查把关 12. 9 在沟、坑、槽 1 米内推土、堆料、停置 机具 违章操作 坍塌 Ⅱ 3 1 7 21 一般 现场检查把关 13. 二 主 体 施 工 1 基 础 施 工 作 业 10 机械设备施工与槽边距离不符合规定, 又无措施 违章指挥 坍塌 Ⅱ 3 1 15 45 一般 现场检查把关 2 工 程 处 危 险 因 素 识 别 评 价 表 ( 民 用 建 筑 部 分 ) 编号: 危 险 因 素 识 别 作业条件危险性评价 序 号 作业活动 序 号 因 素 类 别 可能导致的 事 故 判别依 据(Ⅰ- Ⅴ) L E C D 危险 级别 现有控制措施 备注 14. 11 未设置有效的排水措施 管理缺陷 坍塌 Ⅱ 3 6 3 54 一般 现场检查把关 15. 12 深度超过 5 米,面积 1000 平米以上的 工程,未审核备案 管理缺陷 坍塌 Ⅰ 1 1 15 15 稍有 按规定审核把关 16. 13 人工挖桩孔时孔内有窒息气体 管理缺陷 窒息性中毒 Ⅱ 3 6 3 54 一般 岗前培训,通风作业,加强 监督管理 17. 14 人工挖扩桩孔,孔壁无支护 防护缺陷 坍塌 Ⅱ 1 6 7 42 一般 现场检查把关 18. 15 挖土机挺杆旋转范围内有人作业 违章作业 机械伤害 Ⅱ 1 3 7 21 一般 现场检查把关 19. 16 柱孔内电、气焊作业,无措施 违章作业 火灾/窒息 Ⅱ 3 1 15 45 一般 按规定审核把关 20. 17 装、运、回填、破碎引发粉尘超 标排放 违章作业 尘肺 Ⅱ 3 2 7 42 一般 按规范检查把关 21. 1 无脚手架搭设和拆除方案 管理缺陷 倒塌/高处坠落 Ⅱ 3 1 15 45 一般 按规定审核把关 22. 2 违反安全技术措施与方案操作 违章作业 倒塌 Ⅳ 6 2 15 180 显著 按规定审核把关 23. 3 使用不合格的钢管扣件 违章作业 倒塌 Ⅱ 3 6 3 54 一般 现场检查把关 24. 4 脚手架基础未平整夯实,无排水 措施 管理缺陷 违章作业 倒塌 Ⅳ 2 6 15 180 显著 现场检查把关 25. 5 脚手架底部未垫木和未加扫地杆 防护缺陷 倒塌 Ⅱ 3 2 3 21 一般 按规范现场检查把关 26. 6 脚手架底部的垫木和扫地杆不符 合要求 防护缺陷 倒塌 Ⅱ 3 10 1 30 一般 按规范现场检查把关 27. 主 体 施 工 7 架体与建筑物拉接不符合要求 防护缺陷 倒塌 Ⅱ 3 3 7 63 一般 按规范现场检查把关

分类:安全管理制度 行业:建筑加工行业 文件类型:Word 文件大小:337 KB 时间:2025-12-17 价格:¥2.00

附件:建筑施工安全生产大督查大执法重点行为检查清单

督查组: 形象进度 业主代表姓名 与联系电话 项目经理姓名 与联系电话 项目总监姓名 与联系电话 设计单位 检测单位 项目经理本次 记分 序号 本次检 查项 行为主 体 检查项目 主要内容 督查意见 □未办理安全监督手续 □办理安全监督手续滞后 □未办理施工许可 □施工许可办理滞后 □建设范围超出施工许可允许范围 □未在施工合同中单列安全文明施 工费; □未在开工前将安全文明施工费拨 付给施工单位 □未检查安全文明施工费使用情况 并督促落实安全文明施工措施。 □未参与对危大工程安全管理 □接到安全隐患报告后,未督促施 工单位立即整改 □应实行第三方监测的未按规定进 行监测 □应组织相关评估、论证而未组织 的 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □不符合 □不符合 □不符合 □不符合 安全报监资料 施工许可证 支付凭证、检查记 录 相关审查、检查资 料与工作记录 办理安全监督手 续情况 施工许可办理 安全文明施工费 危大工程安全管 理 建 设 单 位 □ □ □ □ 一、建设单位安全生产重点行为 检查情况 □符合 □符合 □符合 □符合 1 2 3 4 分包单位 监测单位 监理单位 重庆市建新建设监理咨询有限公司 乔守江 勘察单位 建设单位 重庆市宏安房地产开发有限公司 杨义彬 施工单位 重庆市荣昌区华兴建筑工程有限公司 刘杰 附件 建筑施工安全生产大督查大执法重点行为检查清单 督查时间: 年 月 日 督查地区: 工程名称 广顺虹杉园 1#楼主体、2#楼主体 第 1 页,共 6 页 □未收集并提供施工现场、毗邻区 域地下管线和建(构)筑物准确、 完整的现状资料 □应督促制定安全保护措施方案而 未督促的 □不符合 □未按照《关于进一步加强城市轨 道交通工程关键节点风险管控工作 的通知》(渝建〔2017〕639号), 开展正式核查工作。 序号 本次检 查项 行为主 体 检查项目 主要内容 督查意见 □超出资质许可范围承担业务 □资质证书不在有效期内 □施工企业未取得或因故被吊销安 全生产许可证 □安全生产许可证不在有效期内 □不符合 □存在违法分包行为 □不符合 □存在转包行为 □人员变更未办理相关手续 □变更人员资格不满足相关规定 □施工单位变更后未重新办理或变 更施工许可证 □变更后的施工单位资质、人员资 格或数量不满足相关规定 □符合 □未建立安全文明施工费使用管理 制度 □未建立安全文明施工费使用计划 □未单独建立安全文明施工费使用 台账 □未专款专用,将安全文明施工费 挪作他用。 □未建立、落实项目安全生产责任 制 □未确保项目安全生产费用有效使 用 □未有效监控项目危大工程管理 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □整改 □局部停工 □全面停工 □建议立案 处罚 □不符合 □不符合 □不符合 □不符合 □不符合 □不符合 □不符合 施工许可证、单位 资质证书、人员资 格证书 相关制度、计划、 台账等资料 安全生产责任制、 安全生产带班记录 、安全考核记录等 安全台账与现场 核查资料 施工单位资质证书 安全生产许可证 人员变更手续和变 更人员资格 相关审查、检查资 料与工作记录 安全文明施工费 项目经理安管职 责履行 施工单位资质 安全生产许可 违法分包 转包 施工单位人员变 更 施工单位变更 既有建(构)筑 物或管线安全管 理 轨道工程关键节 点风险管控 施 工 单 位 (一) □ □ □ □ □ □ □ □ □ □ 9 10 11 12 13 14 □符合 □符合 □符合 □符合 □符合 □符合 □符合 二、施工单位安全生产重点行为 检查情况 □符合 □符合 5 6 7 8 第 2 页,共 6 页

分类:安全管理制度 行业:建筑加工行业 文件类型:Excel 文件大小:43.5 KB 时间:2026-01-02 价格:¥2.00

安全员全套资料-临时用电施工组织设计方案示例2

邯鄣市供电公司 2#高层信宅楼 临时用电施工组织设计 施工单位:中煤建安第六十九工程处 一、 编制依据: 1. 施工现场临时用电安全技术规范(JGJ46-88); 2. 建筑施工安全检查标准(JGJ59-99); 3. 河北省建筑施工安全检查标准实施细则; 4. 《施工现场临时用电施工组织设计》(徐荣杰编) 二、 工程概况: 1. 本工程位于邯鄣市东大街西侧、丛台路北 500 处,为高层家属住宅楼。 地上十九层,楼向座北向南,总建筑面积 10504 平方米。施工用电配电室设在主体施工现场 的东侧北角,配电室总电源由建设单位供给。 2. 用电专业设计范围 380/220V 供配电设计,现场用电分设备用电、施 工照明用电。动力用电分 6 路,照明分 3 路,施工用电线路采用 TN-S 接零保护系统。 三、 配电系统施工布置: 1.第一路混凝土搅拌站。橡皮铜芯电缆由配电室架设到搅拌站二极配电箱。 由二级电箱分 6 路分别(埋地)向木工加工车间、混凝土搅拌站供电。   2.第二路户处电梯。橡皮铜芯电缆由配电室架设到户处电梯侧二极配电箱供电梯专用。 3. 第三路钢筋加工车间。橡皮铜芯电缆室架设到户处电梯侧二极配电箱。 由二极电箱分 7 路分别对弯曲、切断和对焊机供电。 4. 第四路塔吊。橡皮铜芯电缆由配电室架设到塔吊侧二级配电箱,由二级 配电箱分 3 路分别向塔吊供电,两路备用开关。 5. 第五路电焊加工车间。橡皮铜芯电缆由配电室架设到电焊加工车间二极 配电箱,由二极箱分两路路供电焊机三级开关箱。3 路备用。 6. 第六路振捣电机。橡皮铜芯电缆由五路备用开关架设至主体施工现场, 分别引到三极漏电开关箱供振捣电机用电。 施工所有设备用电采用三级用电二极保护。三级开关箱:一机一闸一漏一 箱配电。详见临电施工平面图。 四、 负荷计算: 每一路:混凝土搅拌站、木机加工车间用电设备总功率为 91.3 千瓦,选电 缆截面为(3×50+2×25) P 机千瓦 五、 配电室设备:总负荷:180 千瓦 1. 配电室高度大于 3m。 2. 成排与电屏。电屏之间应采用不小于 6m2 铜芯导线相互连接与接地线连 接。 3. 配电屏正面的操作宽度不应小于 1.5m,通过人通道不小于 0.6m。配电室门向外开 并配锁。 4. 满足供电运行可靠、操作灵活、检修方便、有专人值班。 六、 电缆、电线敷设: 1. 避免电缆受到各种损坏及腐蚀,避开规划中建筑工程需要挖掘施工地土 方。 2. 电缆在室外直埋地敷设的浓度不小于 0.6m,并在电缆上下均匀铺设不 小于 0.5m 厚的细砂,然后覆盖砖硬质板物保护。 3. 电缆穿越建筑道路易受机械损伤的场所引出地面 2m 高度到地下 0.2m 处必须加设防护套管。 4. 地埋电缆严禁有接头。 5. 橡皮电缆架空敷设时应沿墙或电杆设置,应用绝缘子固定,严禁使用金 属体线作绑线。 七、 室内配线: 1. 室内配线必须使用绝缘导线,采用瓷瓶、瓷夹等敷设,距在面高度不得 小于 2.5m。 2. 进户线过墙应穿保护套管,并应采取防雨措施。 3. 室内配线所用导线截面铝线截面不小于 2.5m2,铜线截面不小于 155m2。 4. 潮湿场所埋地非电缆配线处必须穿客敷设。管口应密封,采用金属管敷 设时必须做保护接地线。 八、 室外配电箱设置: 1. 配电箱应设置在干燥、通风及常温场所,不得设在强烈振动的场所。 2. 配电箱周围应足够两人同行的空间,不得堆放任何防碍操作、维护物品,

分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:31.5 KB 时间:2026-01-18 价格:¥2.00

安全员全套资料-施工升降机安装自检表GDAQ209010801

(公章) 项不合格。 检查结论 自检人员 (安装单位专业 技术人员) 安装 单位 (签名) 检查情况 汇 总 检查项目共计99项: 保证项目共38项,第 项不合格,共 项不合格; 一般项目共61项,第 项不合格,共 检 查 依 据 1.《建筑施工升降机安装检验评定规程》 2.《施工升降机安全规程》GB 10055-2007 3.《施工升降机》GB/T 10054—2005; 4.《起重机械安全规程 第1部分:总则》GB 6067.1-2010 5.《建筑机械使用安全技术规程》JGJ 33-2001 6.《建筑施工升降机安装、使用、拆卸安全技术规程》JGJ 215-2010 7.《施工现场机械设备检查技术规程》JGJ 160-2008 8.《建筑起重机械安全监督管理规定》(建设部令第166号) 设 备 状 态 导轨架架设高 度: m;安全器编号: ; 安全器型号: 安全器有效期: 人;最大独立高度: m 最大提升高度: m;导轨架顶端自由高度: m 安 装 位 置 性 能 参 数 额定载重量: kg;额定提升速度: m/min 额定乘员数: 备 案 编 号 出厂日期 告知受理号 设备自编号 SS型驱动形式 0 0 制造编号 型 号 规 格 传动形式 0 0 0 产 权 单 位 制 造 单 位 (许可证号: 工 程 地 址 使 用 单 位 安 装 单 位 施工升降机安装自检表 GDAQ209010801 工 程 名 称 序号 ★1 2 3 5 7 9 10 1.2.2 限载标志 应在施工升降机明显部位设置限载、限人标志 卷筒两侧边超出最外层钢丝绳的高度不应小于钢丝 绳直径的两倍 1.2 信息标 志与信 号 1.2.1 产品标牌 应在升降机易于观察的位置设置耐腐蚀的金属产品 标牌,其内容应包括:产品名称和型号;产品主要 性能参数;产品出厂编号;产品制造日期;制造商 名称 1.1.7 对重导轨 对重导轨不得采用链条或钢丝绳等柔性物体 8 1.1.8 钢丝绳防 脱装置 滑轮、卷筒或曳引轮应有钢丝绳防脱装置,该装置 与滑轮、卷筒或曳引轮外缘的间隙不应大于钢丝绳 直径的20%,且不大于3mm 1.1.5 吊笼底板 吊笼底应防滑、排水,不得存有破损等缺陷 6 1.1.6 吊笼与 对重导向 吊笼与对重的导向应正确可靠,吊笼采用滚轮导向, 对重可采用滚轮或滑靴导向 吊笼不允许当作对重使用 吊笼应封顶,吊笼顶应设置高度不小于1.1m的护栏, 护栏的中间高度应设横杆,踢脚板高度不小于100mm ★4 1.1.4 紧急逃 离出口 吊笼顶部应设有紧急出口,并配有专用扶梯。出口 应装有向外开启的活板门,并设有电气安全开关,且 动作有效、可靠 当吊笼顶部未设紧急出口时,应在吊笼立面上装设 紧急逃离门,门应向吊笼内侧打开或采用滑动型的 门,并设有电气安全开关,且动作有效、可靠 1.1 结构 1.1.1 主要受力 构件 施工升降机导轨架、传动系统、吊笼立柱、上下承 载梁和附墙架等主要受力构件不得有明显变形、可 见裂纹、开焊和严重锈蚀、磨损等缺陷。标准节立 管壁厚减少量不得大于出厂厚度的25% 1.1.2 笼门尺寸 吊笼门框的净高度至少为2.0m,净宽度至少为0.6m 吊笼门的开启高度不得小于1.8m 1.1.3 笼顶防护 施工升降机安装自检表 (续表一) GDAQ209010801-1 项 类 项目编号 检 查 内 容 及 要 求 检查结果 结 论 年 月 日 年 月 日 备 注 保证项目(序号带“★”的项目)全部合格,一般项目中不合格项目数不超过5项,此设备自 检 结论方为“合格” 自检人员 (安装单位专业 技术人员) 安装 单位

分类:安全管理制度 行业:其它行业 文件类型:Excel 文件大小:132 KB 时间:2026-01-26 价格:¥2.00

安全员全套资料-6附着整体和分片提升手架安装搭设施工技术交底GDAQ330306

附着式整体和分片提升脚手架安装搭设施工技术交底 GDAQ330306 施工单位: 工程 名称 分部分项 工  程 工种 一、进入施工现场必须遵守安全操作规程和安全生产纪律,特种作业人员必须持证上岗。 二、根据工程特点与使用要求编制专项施工组织设计。对特殊尺寸的架体应进行专门设计,架体在使用过 程中因工程结构的变化而需要局部变动时,应制定专门的处理方案。 三、根据施工组织设计要求,落实现场施工人员及组织机构。 四、核对脚手架搭设材料与设备的数量、规格,查验产品质量合格证(出厂合格证)、材质检验报告等文件 资料,必要时应进行抽样检验。主要搭设材料应满足以下规定: (一)脚手管外观表面质量平直光滑,没有裂纹、分层、压痕、硬弯等缺陷,并应进行防锈处理;立杆最 大弯曲变形应小于 L/500,横杆最大弯曲变形应小于 L/150;端面平整,切斜偏差应小于 1.70mm;实际壁厚 不得小于标准公称壁厚的 90%; (二)焊接件焊缝应饱满,焊缝高度符合设计要求,没有咬肉、夹渣、气孔、未焊透、裂纹等缺陷; (三)螺纹连接件应无滑丝、严重变形、严重锈蚀等现象; (四)扣件应符合现行《钢管脚手架扣件》GB 15831 的规定; (五)安全围护材料及其他辅助材料应符合相应国家标准的有关规定。 五、准备必要的电工工具、机械工具和机电设备并检查其是否合格,限载控制系统的传感器等在每一个单 体工程使用前均应进行标定。 六、附着升降脚手架安装与拆除需要施工塔吊配合时,应核验塔吊的施工技术参数是否满足需要。 七、附着升降脚手架升降采用电动设备时,应核验施工现场的供电容量。 八、附着升降脚手架安装搭设前,应核验工程结构施工时设置的预留螺栓孔或预埋件的平面位置、标高和 预留螺栓孔的孔径、垂直度等,还应核实预留螺栓孔或预埋件处混凝土的强度等级。预留螺栓孔或预埋件的中 心位置偏差应小于 15mm,预留螺栓孔孔径最大值与螺栓直径的差值应小于 5mm,预留孔应垂直于结构外表面。 不能满足要求时应采取合理可行的补救措施。 九、附着升降脚手架安装搭设前,应设置可靠的安装平台来承受安装时的竖向荷载。安装平台上应设有安 全防护措施。安装平台的水平精度应满足架体安装精度要求,任意两点间的高差最大值不应大于 20mm。 十、附着升降脚手架的安装搭设应按照施工组织设计规定的程序进行。 十一、安装过程中应严格控制水平支承结构与坚向主框架的安装偏差,水平支承结构相邻两机位处的高差 应小于 20mm;相邻两榀竖向主框架的水平高差应小于 20mm;竖向主框架的垂直偏差应小于 3‰;若有竖向导轨, 则导轨垂直偏差应小于 2‰。 十二、安装过程中架体与工程结构间应采取可靠的临时水平拉撑措施,确保架体稳定。 十三、扣件式或碗扣式脚手杆件搭设的架体,搭设质量应符合相关标准的要求。 十四、扣件螺栓螺母的预紧力矩应控制在 40~65N·m 范围内。 十五、作业层与安全围护设施的搭设应满足设计与使用要求。 十六、架体搭设的整体垂直偏差应小于 4‰,底部任意两点间的水平高差不大于 50mm。 十七、脚手架邻近高压线时,必须有相应的防护措施。 十八、现场补充交底内容: 交底人签字: 日 期: 接受人(全员)签字: 注:本交底一式三份,班组、交底人、资料保管员各一份。

分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:47.5 KB 时间:2026-02-24 价格:¥2.00

浅谈施工企业设备管理(DOC 7)

www.cnshu.cn 中国最庞大的下载资料库 (整理. 版权归原作者所有) 如果您不是在 cnshu.cn 网站下载此资料的, 不要随意相信. 请访问 cnshu 加入 cnshu.cn 必要时可将此文件解密成可编辑的 doc 或 ppt 格式 浅谈施工企业设备管理   “工欲善其事,必先利其器”,构成企业生产力要素之一的机械 设备是企业进行生产的主要手段,也是企业不断提高劳动生产率,提 高企业经济效益的重要物资基础。诚然,企业要振兴和发展,就要有 精良的设备和不断强化设备管理,保证设备完好率,对于生产力三大 要素“人、机、物”中的“机”的研究,已被越来越多的建筑施工企 业家所认识和重视。   笔者依据长期从事建筑施工管理的实践经验和学习掌握的机械 设备管理理论知识,拟对建筑施工企业设备管理这一课题,撰写本文 抒之己见,旨在探讨和商榷。   一、建筑施工企业的设备管理,要结合施工企业的特点,立足于 升华企业群体设备管理意识   施工企业不同于其他工业企业,因此建筑施工企业的设备管理, 它具有自身的特点。建筑施工企业的特点是:施工地点分散、不固定, 人员设备流动,工序之间要求衔接紧,需要工种配套、多工种联合作 业。况且露天高空、交叉作业多,受季节影响大。这就要求施工企业 www.cnshu.cn 中国最庞大的下载资料库 (整理. 版权归原作者所有) 如果您不是在 cnshu.cn 网站下载此资料的, 不要随意相信. 请访问 cnshu 加入 cnshu.cn 必要时可将此文件解密成可编辑的 doc 或 ppt 格式 必须根据本企业的特点,扬长避短。采用管理大批量生产,按工艺专 业化组织的设备管理方法来管理施工企业的设备,显然是行不通的。 由于建筑施工企业的建筑产品投资多、体积大、生产的周期长,而且 产品不能流水线式的大批量生产。这一特点就决定了施工企业的机械 动力设备,要按施工对象组织专业化设备,进行设备管理。升华形成 企业群体设备管理意识,导向实施严格设备管理。这是施工企业设备 管理的不容忽视的工作内容。   意识产生需要,需要产生动机,动机导向行为,这是连锁反映, 密不可分的。意识是先导,只有意识高,需要才能明确,动机才能坚 定,行动才能快速,这是现代心理学揭示的基本规律。工欲善其事, 必先利其器,随着科学技术的进步和现代化建设步伐的加快,建筑产 品向地上高层和地下深层发展已成定势。靠手推肩扛的手工劳动和延 长劳动时间,增加劳动强度来提高劳动生产率,已经不现实了。施工 项目要低耗、优质、快速的交竣工,必然要选择投入高精尖施工设备 和管理好这些先进设备势在必行。提高企业群体设备意识,统一思想, 形成共识,这对强化“全员设备管理”是极为重要的。   二、推行设备承包、专人、专机负责制,是建筑施工企业严格设 备使用,强制设备保养的一个有效方法

分类:安全管理制度 行业:其它行业 文件类型:Word 文件大小:34.5 KB 时间:2026-03-09 价格:¥2.00

项目施工安全管理实践

项目施工安全管理实践 1 概述   安全生产长期以来一直是我国的一项基本国策,是保护劳动者安全健康和发 展生产力的重要工作,必须贯彻执行;同时也是维护社会安定团结,促进国民经 济稳定、持续、健康发展的基本条件,是社会文明程度的重要标志。   建筑业是我国社会主义经济建设时期的支柱产业,在我国职业伤害事故中, 建筑业事故伤害仅次于矿山位居第二。随着我国建筑业和建设管理体制改革的不 断深化,建筑业企业的生产方式和组织结构发生了深刻的变化,其中建筑业的安 全生产更是在理论研究和实践应用也愈来愈得到了各方面的重视,并在实践中不 断发展和完善。   建筑施工从业人员绝大多数来自农村,人员流动频繁,文化素质参差不齐, 安全和自我保护意识差,都是导致建筑企业事故发生的主要因素。   项目施工是建筑施工企业生产的最前沿阵地,项目安全管理是项目管理的一 项重要的工作,如何应对日益突出的安全事故,强化项目安全管理,是每一个项 目管理人员,尤其是安全管理人员的当务之急。   2 项目施工安全的重要性   安全与生产的关系是辩证统一的关系,而不是对立的、矛盾的关系,安全与 生产的统一性表现在:一方面指生产必须安全,而另一方面安全可以促进生产。 我国安全生产方针经历了一个从“安全生产”到“安全第一、预防为主”的产生 和发展过程,且强调在生产中要做好预防工作,尽可能将事故消灭在萌芽状态之 中。   为适应社会主义市场经济的需要,1993 年国务院将原来的“国家监察、行 政管理、群众监督”的安全生产管理体制,发展为“企业负责、行政管理、国家 监察、群众监督”。同时,又考虑到许多事故发生的原因,是由于劳动者不遵守 规章制度,违章违纪造成的,所以增加了“劳动者遵章守纪”这一条规定。由此 可见,随着社会主义现代划化建设的需要,国家也在逐步完善安全生产监察制度, 愈加重视安全生产,并专门成立了安全生产监督委员会,从原来的劳动部脱离直 接划归国务院管理。我国 1997 年 11 月 01 日颁布的《中华人民共和国建筑法》, 对建筑施工企业的安全生产管理作出了明确规定,反映出国家对建筑施工企业关 乎民生问题的重视,通过立法确立了建筑施工企业安全管理制度的重要性。   “安全第一,预防为主”是企业安全生产的工作方针,但现在仍有许多企业 对安全生产不够重视,安全投入不足,其实主要是项目领导在项目管理掌舵的同 时,没有认清安全与企业经营、项目施工管理紧扣相连的普遍反映。建筑施工企 业在完善企业规章制度的前提下,相应不同的建设工程,建立起施工现场的安全 生产保证体系,保证企业安全生产和创造效益,创建优良工程,树立起企业品牌 和行业信誉,提高市场竞争力。因此,安全生产管理是建筑施工企业生存和发展 的保证。   3 项目安全管理制度建立与运作   要做好施工项目的安全管理,首先要建立起完善的安全管理体系。工程施工 现场安全生产管理体系是施工企业和施工现场整个管理体系的一个组成部分,包 括为制定、实施、审核和保持“安全第一,预防为主”方针和安全管理目标所需 的组织结构、计划活动、职责、程序、过程和 资源。   施工现场安全生产管理体系的建立不仅是为了满足工程项目部自身安全生 产的要求,同时也是为了满足相关方(政府、投资者、业主、保险公司、社会) 对施工现场安全生产管理体系的持续改善和安全生产保证能力的信任。   搞好项目施工安全生产,领导是关键。建立健全以项目经理为首的分级负责 安全生产管理保证体系,同时建立和健全专管成线、群管成网的安全管理组织机 构,是项目施工安全管理的前提条件。根据上述原则,项目经理为安全生产的第

分类:安全管理制度 行业:建筑加工行业 文件类型:Word 文件大小:36.5 KB 时间:2026-03-31 价格:¥2.00

2022年一级消防工程师《消防安全技术实务》试题

1 一、单选题 1.自动喷水灭火系统属于开式系统的是( )。 A.干式系统 B.湿式系统 C.预作用系统 D.雨淋系统 答案:D 【解析】干式、湿式、预作用属于闭式系统,雨淋系统属于开式系统,选用的是开式喷头。 2.某修车库建筑面积为 1800m2,设有 10 个维修车位。根据现行国家标准《修车库、修车库、停车 场设计防火规范》(GB50067),该修车库应属于( )类修车库。 A.I 类 B.II 类 C.Ⅲ类 D.IV 类 答案:B 【解析】 3.下列场所应急照明灯具可独立配电回路的是( )。 A.封闭楼梯间 B.敞开楼梯间 C.消防电梯前室 D.疏散走道 答案:A 【解析】  3.3.3 水平疏散区域灯具配电回路的设计应符合下列规定: 1 应按防火分区、同一防火分区的楼层、隧道区间、地铁站台和站厅等为基本单元设置配电回路; 2 除住宅建筑外,不同的防火分区、隧道区间、地铁站台和站厅不能共用同一配电回路; 3 避难走道应单独设置配电回路; 4 防烟楼梯间前室及合用前室内设置的灯具应由前室所在楼层的配电回路供电; 5 配电室、消防控制室、消防水泵房、自备发电机房等发生火灾时仍需工作、值守的区域和相关 疏散通道,应单独设置配电回路。   3.3.4 竖向疏散区域灯具配电回路的设计应符合下列规定: 1 封闭楼梯间、防烟楼梯间、室外疏散楼梯应单独设置配电回路; 2 敞开楼梯间内设置的灯具应由灯具所在楼层或就近楼层的配电回路供电; 3 避难层和避难层连接的下行楼梯间应单独设置配电回路。 2 4.下列建筑场所中,可不设置消防电梯的是( )。 A.建筑高度为 26m 的病房楼 B.设在第五层且建筑面积 3500m2 的老年人照料设施 C.埋深 12m 且总建筑面积为 5000m2 的地下商场 D.建筑高度为 32m 的住宅 答案:D 【解析】下列建筑应设置消防电梯: 1 建筑高度大于 33m 的住宅建筑;D 错误。 2 一类高层公共建筑和建筑高度大于 32m 的二类高层公共建筑、5 层及以上且总建筑面积大于 3000m²(包括设置在其他建筑内五层及以上楼层)的老年人照料设施;AB 正确。 3 设置消防电梯的建筑的地下或半地下室,埋深大于 10m 且总建筑面积大于 3000m²的其他地下或 半地下建筑(室)。C 正确 5.下列无机物中,属于一级氧化性物质的是( )。 A.过氧化钠 B.重硌酸钾 C.氧化银 D.连二硫酸钠 答案:A 【解析】按物质形态划分:氧化性物质可分为固体氧化性物质和液体氧化性物质。根据氧化性能 强弱,无机氧化性物质通常分为两级:一级主要是碱金属或碱土金属的过氧化物和盐类,如过氧 化钠、高氯酸钠、硝酸钾、高锰酸钾等;除一级外的所有无机氧化剂均为二级氧化性物质,如亚 硝酸钠、亚氯酸钠、连二硫酸钠、重硌酸钠、氧化银等。 6.下列装修材料可以作为 A 级材料使用的是( )。 A.玻镁板 B.珍珠岩板 C.玻璃棉板 D.岩棉装饰板 答案:A 【解析】表 2-10-3 常用建筑内部装修材料燃烧性能等级划分举例: 3 7.对于有爆炸危险的厂房和库房选用耐火性能好、抗爆能力强的框架结构可以在发生火灾爆炸事 故时有效地防止建筑结构发生倒塌破坏,减轻甚至避免危害和损失。耐爆框架结构形式不包括(  )。 A.现浇式钢筋混凝土结构 B.装配式钢筋混凝土结构 C.钢框架结构 D.砖木结构 答案:D 【解析】耐爆框架结构一般有以下三种形式: (1)现浇式钢筋混凝土框架结构。 (2)装配式钢筋混凝土框架结构。 (3)钢框架结构。 8.中型方向标志灯的标志面与疏散方向垂直时,标志灯的最大设置间距( )。 A.15 B.10 C.30 D.20 答案:D 【解析】方向标志灯的标志面与疏散方向垂直时,特大型或大型方向标志灯的设置间距不应大于 30m,中型或小型方向标志灯的设置间距不应大于 20m;方向标志灯的标志面与疏散方向平行时, 特大型或大型方向标志灯的设置间距不应大于 15m,中型或小型方向标志灯的设置间距不应大于 10m。 9.气体灭火系统的驱动装置不包括( )。 A.气动装置 B.电爆型装置 C.液动装置

分类:安全管理制度 行业:建筑加工行业 文件类型:未知 文件大小:1.28 MB 时间:2026-04-26 价格:¥2.00